Transponder-kodirani sigurnosni prekidači sa zaključavanjem


Transponder-coded safety switches with guard locking ( Mechanical guard locking OR Electromagnetic guard locking) and Evaluation devices and gateways.

EUCHNER Straight actuator for safety switch CTP/CTA, A-C-H-G-SST-126015 ACTUATOR; 126015

Straight actuator for safety switch CTP/CTA, A-C-H-G-SST-126015 ACTUATOR; 126015
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Hinged actuator for safety switch CTP/CTA, A-C-H-RR-LS-122672 ACTUATOR; 122672

Hinged actuator for safety switch CTP/CTA, A-C-H-RR-LS-122672 ACTUATOR; 122672
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Hinged actuator for safety switch CTP/CTA A-C-H-RO-LS-122675 (Order no. 122675)

Hinged actuator for top-hinged doors Two safety screws included
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Hinged actuator for safety switch CTP/CTA A-C-H-RU-LS-122676 (Order no. 122676)

Hinged actuator for bottom-hinged doors Two safety screws included
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Actuator CET-A-BWK-50X ; 096327

Actuator CET-A-BWK-50X ; 096327 Actuator for read head/safety switch CET Four M5x16 safety screws included in scope of delivery
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Emergency release for CET AE-M-CET-103714 (Order no. 103714)

Emergency release for CET AE-M-CET-103714
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER IO-Link Gateway for BP/BR switches GWY-CB-1-BR-IO-165049; 165049

IO-Link Gateway for BP/BR switches IO-Link device for reading process and device data of BP/BR safety switches and transferring them to a higher-level control system
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Variable magnetic guard locking device CEM-M2-C60-KZ-SE-163252; 163252

Variable magnetic guard locking device CEM-C60 without permanent magnet, plug connector on left Magnetic guard locking for process protection Locking force 650 N
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Variable magnetic guard locking device CEM-M2-C60-PZ-SE-161320; 161320

Variable magnetic guard locking device CEM-C60 with permanent magnet, plug connector on left Magnetic guard locking for process protection Guard locking solenoid
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Variable magnetic guard locking device CEM-M2-C60-PZ-SE-165746; 165746

Variable magnetic guard locking device CEM-C60 with permanent magnet, plug connector on right Magnetic guard locking for process protection Guard locking solenoid
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER IO-Link Gateway with relay outputs for BP/BR switches ESM-CB-AZ-FI2-BR-IO-158875; 158875

IO-Link Gateway with relay outputs for BP/BR switches IO-Link device for reading process and device data of BP/BR safety switches and transferring them to a higher-level
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTM-LBI-BP-M-AZ-SA-166088; 166088

Transponder-coded safety switch CTM-LBI-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTM-LBI-BP-M-AZ-SA-166090; 166090

Transponder-coded safety switch CTM-LBI-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTM-LBI-BP-U-AZ-SA-166087; 166087

Transponder-coded safety switch CTM-LBI-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTM-LBI-BP-U-AZ-SA-166089; 166089

Transponder-coded safety switch CTM-LBI-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with
-
Need to order

(Trenutno nema na stanju)

Cena na upit


Stranica 1 od 12
Prikazano 1 - 15 od 174 podataka

Transponder-kodirani sigurnosni prekidači sa zaključavanjem


 
 

Subcategories


 

 
 
 
 
 

 CEM-C60 series - Variable magnetic guard locking


 AR evaluation unit


 IO-Link Gateways for BP switch or BR switch chain








------------- Documentation -------------

Catalogs:

CTP and CTA Transponder-Coded Safety Switches with Guard Locking
Transponder-coded safety switch CTM with guard locking (PDF)
One fits all - Safety switch CTS with FlexFunction (PDF)
Transponder-coded safety switch CTP/CTA with guard locking (PDF)
Especially strong – the media-resistant stainless-steel CTP (PDF)
Transponder-coded safety switch CET with guard locking (PDF)
Transponder-coded safety systems - CEM with guard locking for process protection (PDF)
Transponder-coded safety switches - Interlocking devices and guard locking devices
Transponder-coded safety systems - CEM with guard locking for process protection
Connecting cables with M12 plug connectors according to AIDA standard (PDF)
Safety Switches with AS-Interface
Future-proof Communication – Industry 4.0

Instructions:

Operating Instructions AR Evaluation Unit CES-AR-AES-12
Operating Instructions Transponder-Coded Safety Switch, Guard Locking for Process Protection CEM-AR Unicode/Multicode/CEM-AY Unicode
Operating Instructions Variable Magnetic Guard Locking Device CEM-C60
Transponder-Coded Safety Switch with Guard Locking CET.-AP-… (Unicode/Multicode)
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CET.-AR-… (Unicode/Multicode)
Operating Instructions Transponder-Coded Safety Switch With Guard Locking CET.-AS-… (Unicode/Multicode)
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BP Uni-/Multicode V1.0.X up to V1.3.X and CTA-L1/2-BP Uni-/Multicode V1.0.X up to V2.1.X
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BP Unicode/Multicode V1.4.X to V1.5.X, CTA-L1/2-BP Unicode/Multicode V2.2.X to V2.3.X
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BR Unicode/Multicode V1.0.X up to V1.3.X and CTA-L1/2-BR Unicode/Multicode V1.0.X up to V2.1.X
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BR Unicode/Multicode V1.4.X to V1.5.X, CTA-L1/2-BR Unicode/Multicode V2.2.X to V2.3.X
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTM-L2-AS1B Unicode/Multicode
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTM-I2-AS2B Unicode/Multicode
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTM-LBI-BP/BR Unicode/Multicode with control of guard locking via control input IMP
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTM-C2-BP/BR-FLX High/Low Coding Level
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTM-CBI-BP/BR-FLX High/Low Coding Level
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTM-L2-BP/BR Unicode/Multicode
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTM-I2-BP/BR Unicode/Multicode
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTM-LBI-BP/BR-..D Unicode/Multicode with control of guard locking via IO-Link
Transponder-Coded Safety Switch With Guard Locking CTP-AP Unicode/Multicode
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTP-I.-AP Unicode/Multicode
Operating Instructions Transponder-Coded Safety Switch With Guard Locking CTP-AP-...-EX Unicode/Multicode
Operating instructions Transponder-Coded Safety Switch With Guard Locking CTP-LBI-AP Unicode/Multicode
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BP Uni-/Multicode V1.0.X up to V1.3.X and CTA-L1/2-BP Uni-/Multicode V1.0.X up to V2.1.X
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BP Unicode/Multicode V1.4.X to V1.5.X, CTA-L1/2-BP Unicode/Multicode V2.2.X to V2.3.X
Operating instructions Transponder-Coded Safety Switch With Guard Locking CTP-AR Unicode/Multicode
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L.-AS Unicode/Multicode
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTP-I.-AS Unicode/Multicode
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BP Uni-/Multicode V1.0.X up to V1.3.X and CTA-L1/2-BP Uni-/Multicode V1.0.X up to V2.1.X
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTP-I.-BP Unicode/Multicode V1.3.X
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BP Unicode/Multicode V1.4.X to V1.5.X, CTA-L1/2-BP Unicode/Multicode V2.2.X to V2.3.X
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTP-I.-BP Unicode/Multicode V1.4.X
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BR Unicode/Multicode V1.0.X up to V1.3.X and CTA-L1/2-BR Unicode/Multicode V1.0.X up to V2.1.X
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BR Unicode/Multicode V1.4.X to V1.5.X, CTA-L1/2-BR Unicode/Multicode V2.2.X to V2.3.X
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTS-C2-BP/BR-FLX High/Low Coding Level
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTS-C1-BP/BR-FLX High/Low Coding Level
Cable Length Transonder-Coded Safety Switch CTS-C1-BR-…-.SA
Cable Length Transonder-Coded Safety Switch CTS-C2-BR-…-.SA
Operating Instructions Safety Relay with IO-Link ESM-CB
Safety Information and Maintenance ESM-CB
Operating Instructions BR/IO-Link Gateway GWY-CB-1-BR-IO

Applications:

Connection of ESM-CB-AZ-FI2-BR-IO-158875 to SIEMENS I/O-Link master
Connection of CTM-LBI-BP-.. to Safety Relay ESM-BA..1 from V1.0.0
Connection of CTM-LBI-BR-.. to Safety Relay ESM-BA..1
Connection of CTM-LBI-BR-.. to Siemens ET 200SP
Connection CTP-L1-AP-.. to Siemens ET200SP
Connection of CTP-L1..-AR to Siemens ET 200S
Connection of serial wired CTP-L1..-AR to Siemens ET 200S
Connection of CTP-L2..-AR to Siemens ET 200S
Connection of serial wired CTP-L2..-AR to Siemens ET 200S
Connection of CTP-L1..-AR to Siemens ET 200S
Connection of serial wired CTP-L1..-AR to Siemens ET 200S
Connection of CTP-L2..-AR to Siemens ET 200S
Connection of serial wired CTP-L2..-AR to Siemens ET 200S
Connection of CTP-L1..-AR to Safety Relay ESM-BA..1
Connection of serial wired CTP-L1..-AR to Safety Relay ESM-BA..1
Connection of CTP/CTA-L.-B.-.. to Safety Relays ESM-BA..1 from V1.0.0
Connection of CET3-AP to Siemens ET 200S
Connection of CET4-AP to Siemens ET 200S
Connection of CET3-AP to Siemens ET 200pro
Connection of CET4-AP to Siemens ET 200pro
Connection of CET3-AP to Siemens ET 200S
Connection of CET3-AP to MURR MVK-MPNIO
Connection of CET4-AP to MURR MVK-MPNIO
Connection of CET3-AP to Beckhoff CX1030/CX1010 (EL-module)
Connection of CET3-AP to Siemens ET 200pro
Connection of CET4-AP to Siemens ET 200pro
Connection of CET.-AP-... to BECKHOFF EP1957 From V1.5.0
Connection of CET3-AR to Siemens ET 200S
Connection of CET3-AR to Siemens ET 200S
Connection of CET4-AR to Siemens ET 200S
Connection of CET4-AR to Siemens ET 200S
Connection of CET3-AR to Siemens ET 200S
Connection of CET3-AR to Safety Relay ESM-BA..1
Connection of CET3-AR to safety relay PNOZ s4.1
Connection of serial wired CET3-AR to Safety Relay ESM-BA..1
Connection of serial wired CET3-AR to Safety Relay ESM-BA..1
Connection of CET3-AR to safety relay PNOZ X3.10P
Connection of CET3-AR to safety relay PNOZ X3.10P
Connection of CET4-AR to safety relay PNOZ X3.10P
Connection of CET3-AR to safety relay PNOZ s5
Connection of CET3-AR to safety relay PNOZ s5
Connection of CET4-AR to safety relay PNOZ s5
Connection of CET3-AR to Siemens ET 200S
Connection of CET3-AR to Safety Relay MSR127TP
Connection of CET1-AR to a Safety Relay MSR127TP
Connection of CET3-AR to Pilz PDP67
Connection of serial wired CET3-AR to Safety Relay MSR127TP
Connection of serial wired CET1-AR to Safety Relay MSR127TP
Connection of CET3-AR to Safety Relay ESM-BA..1
Connection of serial wired CET3-AR to Safety Relay ESM-BA..1
Connection of serial wired CET3-AR to Safety Relay PNOZ s4.1
Connection of serial wired CET3-AR to Safety Relay PNOZ X3.10P
Connection of serial wired CET3-AR to Safety Relay PNOZ s5
Connection of serial wired MGB-L1..-AR and CET3-AR to Siemens ET 200S
Connection of serial wired MGB-L1..-AR, CES-AR and CET3-AR to Siemens ET 200S
Connection of CET3-AR to PNOZ Multi
Connection of CET3-AR to Pilz PDP67
Connection of CET3-AR to PNOZ Multi
Connection of CET4-AR to Siemens ET 200SP
Connection of ESM-CB-AZ-FI2-BR-IO-158875 to SIEMENS I/O-Link master

1
2
3
Uporedi proizvode Ukloni sve proizvode