EUCHNER STA4A-2131A024MF-EX ; 115585

Safety switch STA with door monitoring contact, ATEX ATEX version Suitable for usage in zone 2 and 22 (gases and dusts) Auxiliary release on the front With door...

Brand: EUCHNER
Šifra: 115585
Dostupnost: Proveriti dostupnost
Cena na upit

              Safety switch STA with door monitoring contact, ATEX

  • ATEX version
  • Suitable for usage in zone 2 and 22 (gases and dusts)
  • Auxiliary release on the front
  • With door monitoring contact

Approvals

Zulassung EACZulassung c_UL_us LISTEDZulassung CCCATEX

Mechanical values and environment

Housing material Die-cast alloy
Weight  
Net 0,6 kg
Ambient temperature -20 ... 75 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position NC contacts 1
Number of guard lock monitoring positively driven contacts 2
Number of guard lock monitoring NO contacts 1
Connection  
3 x Cable gland M20 x 1.5
Clamping range for cable 6,5 ... 12 mm
Approach speed max.20 m/min
Actuation frequency max.1200 1/h
Guard locking principle Open-circuit current principle
Locking force Fmax 3000 N
Locking force FZh 2300 N
Retention force 20 N
Extraction force 30 N
Actuating force 35 N
Insertion depth min.24,5 mm

Electrical connection ratings

Thermal rated current Ith 4 A
Utilization category according to EN 60947-5-1  
AC-15 4A 50V
DC-13 4A 24V
Solenoid operating voltage  
AC/DC 24 V -15% ... +10%
Short circuit protection according to IEC 60269-1  
(Fuse) 4A gG
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage  
Min. at 10mA 12 V
Switching current  
Min. at 24V 1 mA
Power consumption 8 W
Solenoid duty cycle 100 %
Connection cross-section 0,34 ... 1,5 mm²

Other

Explosion protection  
incl. cable gland II3G Ex nR IIB T4 Gc X /II3D Ex tc IIIC T110°C Dc X

Reliability values according to EN ISO 13849-1

  Monitoring of guard locking and the safety guard position
B10D 11,5 x 106

In combination with Actuator BETAETIGER-S-G-SN-C2115

Mechanical values and environment

Overtravel 5 mm
  • Safety Switches Ex - Catalogue

    Safety Switches Ex - Catalogue

  • Safety Switches Ex - Manual

    Safety Switches Ex - Manual



Slicni proizvodi:


EUCHNER SGA1A-2131A-M-EX ; 123460

Safety switch SGA, ATEX ATEX version Suitable for usage in zone 2 and 22 (gases and dusts) Cable entry M20 x 1.5 Switching disc made of metal
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER STA3A-2131A024MF-EX ; 115584

Safety switch STA with door monitoring contact, ATEX ATEX version Suitable for usage in zone 2 and 22 (gases and dusts) Auxiliary release on the front With door
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER AM-C-C04-EX-137528 ; 137528

Housing protection ATEX ATEX protective cover The protective cover is suitable for all CES-C04-AP/AR switches. The housing protection makes it possible to use safety
-
Need to order

(Trenutno nema na stanju)

Cena na upit

1
2
3
Uporedi proizvode Ukloni sve proizvode