Helmholz Analog input module – AI 2 x I, 0/4–20mA, ±20mA, 12 Bit

Parameters for the module Diagnostic alarm: On | Off Overflow / underflow diagnosis: On | Off Representation values: SIMATIC* S7 | SIMATIC* S5 Parameters for each...

Brand: Helmholz
Šifra: 600-250-4AB01
Dostupnost: Proveriti dostupnost
Cena bez pdv-a: 16.423,83
Cena sa pdv-om: 19.708,60

Parameters for the module

  • Diagnostic alarm: On | Off
  • Overflow / underflow diagnosis: On | Off
  • Representation values: SIMATIC* S7 | SIMATIC* S5

 

Parameters for each channel

  • Wire break detection (only for 4 ... 20 mA): On | Off
  • Interference frequency suppression: None | 10 Hz | 50 Hz | 60 Hz | 400 Hz
  • Measuring ranges: Deactivated | 0 ... 20 mA | 4 ... 20 mA | ±20 mA
  • Limit value alarms enabled: On | Off
  • Upper/lower limit: 16 bit analog value (±27648)
  • Measuring ranges 0 ... 20 mA, 4 ... 20 mA, ±20 mA, individually configurable for each channel
  • Measurement resolution: 11 bit + sign
  • Diagnostic messages
  • Wire break detection (for 4 ... 20 mA)
  • Limit value alarms for each channel
  • A bi-color LED (blue/red) indicates the module operating status and any malfunctions
  • 2 analog inputs for measuring current, electrically isolated from the backplane bus
  • 2 process input words
General information
  Order number 600-250-4AB01
  Article name AI 2x I, 0/4...20 mA, ±20 mA, 12 bit
  Scope of delivery AI 2x I, 0/4...20 mA, ±20 mA, 12 bit
  Dimensions (DxWxH) 110 x 14 x 73 mm
  Weight Approx. 70 g
Number of inputs 2
Electrical isolation
  from the backplane bus Yes
  Between the channels No
Current draw
  External Not needed
  Internal Max. 95 mA
Power dissipation Max. 0.7 W
Measuring ranges / load resistance 0 ... 20 mA / 50 ohms, 4 ... 20 mA / 50 ohms, ±20 mA / 50 ohms
Measuring method Integration
Measurement resolution 11 bit + sign
Interference frequency suppression None | 10 Hz | 50 Hz | 60 Hz | 400 Hz
Refresh rate / conversion rate Number of active channels x conversion time + 16 ms for wire break detection when activated.
The conversion time will depend on the interference frequency suppression:
None: 8 ms
400 Hz: 45 ms
60 Hz: 109 ms
50 Hz: 128 ms
10 Hz: 342 ms
Diagnoses Upper measuring range limit exceeded (overflow), lower measuring range limit fallen below (underflow), wire break (for 4 ... 20 mA only), parameter assignment error
Process alarms Upper and lower limit per channel
Error limits
  Operational error limit in the entire temperature range ±0.5 % relative to the nominal range
  Basic error limit at 25 °C ±0.3 % relative to the nominal range
  Temperature error ±0.005 %/K relative to the nominal range
  Linearity error ±0.05 %/K relative to the nominal range
  Repeating accuracy in steady state at 25 °C ±0.05 %/K relative to the nominal range
Parameter configuration length 12 bytes
General error indicator Red LED
Hot-swap capable Yes
Ambient conditions
  Ambient temperature 0 °C … +60 °C
  Transport and storage temperature -20 °C … +80 °C
  Relative air humidity 95 % r H without condensation
  Protection rating IP 20
  Certifications CE, UL
UL
  Surrounding Air Temperature 0 °C … +60°C
  Pollution degree 2
CE
  Noise immunity DIN EN 61000-6-2 “EMC Immunity”
  Interference emission DIN EN 61000-6-4 “EMC Emission”
  Vibration and shock resistance DIN EN 60068-2-8:2008 “Vibration”, DIN EN 60068-27:2010 “Shock“
  RoHS Yes
  REACH Yes

Slicni proizvodi:


Helmholz Analog input module – AI 2 x U, ±24 V, 0–24 V, 12 Bit

Parameters for the module Diagnostic alarm: On | Off Overflow/underflow diagnosis: On | Off Representation values: SIMATIC* S7 | SIMATIC* S5 Parameters for each
-
Need to order

(Trenutno nema na stanju)

 
 
20.562,12

Helmholz Analog input module – AI 1/2 x R, RTD, 16 Bit, 2/3/4-wire

Parameters for the module Diagnostic alarm: On | Off Overflow/underflow diagnosis: On | Off Representation values: SIMATIC* S7 | SIMATIC* S5 Temperature unit: Celsius
-
Need to order

(Trenutno nema na stanju)

 
 
20.562,12

Helmholz Analog input module – AI 2 x TC, Iso., 16 Bit

Parameters for the module Diagnostic alarm: On | Off Overflow/underflow diagnosis: On | Off Representation values: SIMATIC* S7 | SIMATIC* S5 (for ±80 mV only)
-
Need to order

(Trenutno nema na stanju)

 
 
21.855,33

Helmholz Analog input module – AI 2/4 x R, RTD, 16 Bit, 2/3/4-wire

Parameters for the module Diagnostic alarm: On | Off Overflow/underflow diagnosis: On | Off Representation values: SIMATIC* S7 | SIMATIC* S5 Temperature unit: Celsius
-
Need to order

(Trenutno nema na stanju)

 
 
23.924,48

Helmholz Analog input module – AI 4 x U, ±24 V, 0–24 V, 12 Bit

Parameters for the module Diagnostic alarm: On | Off Overflow/underflow diagnosis: On | Off Representation values: SIMATIC* S7 | SIMATIC* S5 Parameters for each
-
Need to order

(Trenutno nema na stanju)

 
 
23.924,48

Helmholz Analog input module – AI 4 x TC, Iso., 16 Bit

Parameters for the module Diagnostic alarm: On | Off Overflow/underflow diagnosis: On | Off Representation values: SIMATIC* S7 | SIMATIC* S5 (for ±80 mV only)
-
Need to order

(Trenutno nema na stanju)

 
 
25.734,98

1
2
3
Uporedi proizvode Ukloni sve proizvode