EUCHNER MGB-L2CB-PN-L-106224; 106224

Evaluation module with control and bus module MGB-...-PN with 11 controls and indicators, push-pull plug, RC12, MGB-L2CB-PN-L-106224; 106224...

Brand: EUCHNER
Šifra: 106224
Dostupnost: Proveriti dostupnost
Cena na upit

Evaluation module with control and bus module MGB-...-PN with 11 controls and indicators, push-pull plug, RC12, MGB-L2CB-PN-L-106224; 106224

Approvals

c_UL_us_E155795_3/9ProfiNET_Z10141_Version 2023Profisafe_Z20058_Version2024EAC_RU C-DE.HX37.B.14157/20

Workspace

Rated operating distances Sn 20 mm

Operating and display elements

Occupancy diagram  
  B2
  L2
  C3

Item Color Extras Version Slide-in label Note slide-in label Switching element Number Designation1 LED
1 white   Illuminated pushbutton     1NO      
11 Red   Signal indicator            
12 white   Illuminated pushbutton     1NO      
13     Operating mode selector Entsichert / Unsecured ; Sonderfunktion / Special function ; S-Bereich Gesichert / S-Zone Secured   Code 2 of 3      
2 white   Illuminated pushbutton     1NO      
3 white   Illuminated pushbutton     1NO      
4 white   Illuminated pushbutton     1NO      
5 white   Illuminated pushbutton     1NO      
6 white   Illuminated pushbutton     1NO      
7     Emergency stop     2 PD      
8 white   Illuminated pushbutton     1NO      


Electrical connection values

Connecting cable  
Ethernet Profinet I/O cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block  
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Transponder coding Multicode
Degree of contamination (external, according to EN 60947-1) 3
  Power supply X1
Fuse  
external min. 1 A slow blow
Operating voltage DC  
L1 24 V DC -15% ... +10%
Auxiliary voltage DC  
L2 24 V DC -15% ... +10%
  Power supply X2
Operating voltage DC  
L1 24 V DC -15% ... +10%
Auxiliary voltage DC  
L2 24 V DC -15% ... +10%

Mechanical values and environment

Connection type  
  Push-pull power
for enabling switch Plug connector RC12
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45
  Push-pull power
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45
Installation orientation Door hinge DIN left
Switching frequency 0.25 Hz
Mechanical life  
  1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Response time  
Guard locking max. 550 ms Turn-off time
Enabling switch max. 250 ms Turn-off time
Operating mode selector max. 220 ms Turn-off time
Emergency stop / machine stop max. 250 ms Turn-off time
Door position max. 550 ms Turn-off time
Bolt position max. 550 ms Turn-off time
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature  
with UB = 24 V DC -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061


  PL Maximum SIL PFHD Category Mission time
Monitoring of the guard position PL e 3 4.07x10-8 4 20 y
Monitoring of guard locking PL e 3 4.07x10-8 4 20 y
Safe multi-position switch PL e 3 4.1x10-8 4 20 y
Evaluating safety signals PL e 3 4.1x10-8 4 20 y

  B10D Mission time
Emergency stop 0.13x106 20 y

Miscellaneous

Slide-in label  
Number Labeling Note
  S-Zone Secured  
  Line Start  
  Cooling Water Extraction Off  
  S-Zone Reset  
  Safety Gate Open  
  Anlage Stopp  
  Anlage Start  
  Kühlwasser ein  
  Schutztür Öffnen  
  Cooling Water Extraction On  
  S-Bereich Gesichert  
  Kühlwasser aus  
  S-Bereich Quittieren  
  Line Stop  
Product version number V3.30.10

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface Ethernet
 
  • MAN Operating-Instructions-Safety-Systems-MGB… EN 3186715 2114575

    MAN Operating-Instructions-Safety-Systems-MGB… EN 3186715 2114575



Slicni proizvodi:


EUCHNER Escape release module MGB-E-A2 pre-assembled on mounting plate; 106051

euchner-escape-release-module-mgb-e-a2-pre-assembled-on-mounting-plate-106051
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Handle module MGB-H-AA1A3-R-111157; 111157

Handle module MGB-H-...Intelligent bolt tongue, Fold-out lockout mechanism, Second automatically extending lockout mechanism, Door handle
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER MGB-L2B-PNC-L-123012 (Order no. 123012)

Evaluation module and bus module MGB-L2...-PN (guard locking by solenoid force) with 4 control elements, push-pull plug
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1...-PN... (guard locking by spring force) with 3 control elements, 7/8'' and M12 plugs; 121862

euchner-locking-set-mgb-l1...-pn...-(guard-locking-by-spring-force)-with-3-control-elements-7-8-and-m12-plugs-121862
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1...-PN... (guard locking by spring force) with 3 control elements, 7/8'' and M12 plugs, 121858

euchner-locking-set-mgb-l1...-pn...-(guard-locking-by-spring-force)-with-3-control-elements-7-8-and-m12-plugs-121858
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER MGB-L1HB-PNA-R-113230 (Order no. 113230)

Locking set MGB-L1...-PN (guard locking by spring force) with 4 control elements, 7/8" and M12 plugs Guard locking with guard lock monitoring With key-operated
-
Need to order

(Trenutno nema na stanju)

Cena na upit

1
2
3
Uporedi proizvode Ukloni sve proizvode