EUCHNER Locking module MGB-L1-ARA-AL3A1-S8-R-157884; 157884

EUCHNER Locking module MGB-L1-ARA-AL3A1-S8-R-157884; 157884

Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbutton, emergency stop, M12 for enabling switch, RC26 Guard locking with guard lock monitoring...

Brand: EUCHNER
Šifra: 157884
Dostupnost: Proveriti dostupnost
Cena na upit

Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbutton, emergency stop, M12 for enabling switch, RC26

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850
  • 1 illuminated pushbuttons
  • With plug connector RC26
  • With plug connector M12 for enabling switch
  • Unicode

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-09_

Operating and display elements

Occupancy diagram L1
Item Extras Color Designation1 Number LED Note slide-in label Switching element Slide-in label Version
1 with monitoring contact           2 PD + 1 NO   Emergency stop
2             1NO   Illuminated pushbutton

Electrical connection values

Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time  
between FO1A and FO1B max. 10 ms
Utilization category  
DC-13 24V 200mA 
Risk time according to EN 60947-5-3 max. 350 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
  Solenoid control input IMP1, IMP2, IMM
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms
  Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage UA V
Switching current 1 ... 10 mA
LED power supply 24 V DC
  Monitoring outputs OD, OT, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC 
Output current max. 50 mA
  Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B HIGH UB-2V ... UB V DC 
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current  
per safety output FO1A / FO1B 1 ... 200 mA
Test pulse duration max. 1 ms
Test pulse interval min. 100 ms
  Power supply UA
Operating voltage DC  
UA 24 V DC -15% ... +10% 
Current consumption  
IUA max. 375 mA 
  Power supply UB
Operating voltage DC  
UB 24 V DC -15% ... +10% 
Current consumption  
IUB max. 80 mA 

Mechanical values and environment

Connection type  
  Plug connector SFF5 
  Plug connector RC26 
Installation orientation Door hinge DIN right
Switching frequency 0.25 Hz
Mechanical life  
  1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Degree of protection IP65
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
  Control of guard locking
Category 4
Performance Level PL e
PFHD 2.8 x 10-9
  Emergency stop
B10D  
Emergency stop 0.13 x 10⁶
  Monitoring of guard locking and the guard position
Category 4

Slicni proizvodi:


EUCHNER Locking module MGB-L1-ARA-AL1A1-M-R-121100; 121100

Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons incl. label carrier Guard locking with guard lock monitoring Can be connected in
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-ARA-AM5A1-S1-R-121188; 121188

Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1H-ARA-R-117229; 117229

Locking set MGB-L1H-ARA... (guard locking by spring force) with 3 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1H-ARA-R-122236; 122236

Locking set MGB-L1H-ARA... (guard locking by spring force) with 3 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1HE-ARA-R-157888; 157888

Locking set MGB-L1HE-ARA... (guard locking by spring force) with 1 pushbutton, emergency stop, M12 for enabling switch, RC26 Guard locking with guard lock monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-ARA-AC4A1-S1-R-111101; 111101

Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Can be connected in
-
Need to order

(Trenutno nema na stanju)

Cena na upit

1
2
3
Uporedi proizvode Ukloni sve proizvode