Helmholz Function module – 1 x Counter , 5 V (RS422), 4 MHz, 32 bit
Counters are used to detect pulses that are faster than a controller’s cycles, i.e., signals that the controller will be unable to detect properly and that...
Cena bez pdv-a: 23.148,55 |
Cena sa pdv-om: 27.778,26 |
Counters are used to detect pulses that are faster than a controller’s cycles, i.e., signals that the controller will be unable to detect properly and that therefore need to be pre-processed.
The counter module detects the edges of 24 V signals as pulses. The impulses can be counted or converted into a frequency, rotational speed, or period. The counter module features an additional 24 V input and a 24 V output for a direct response to start pulses and to quick system state changes.
Erfassungsmethode
- Pulse & direction
- Rotary encoder with double evaluation
- Rotary encoder with quadruple evaluation
Counting methods
- Continuous counting
- Once-only counting
- Periodic counting
Measuring mode
- Frequency measurement
- Rotational speed measurement
- Period measurement
Synchronization
- Off
- Only-once
- Periodic
- 32-bit counter
- Up to 4 MHz (4-fold evaluation)
- Accommodates 5 V incremental encoders (RS-422)
- Index input
- 5 V supply for sensors
- Filters: 50 kHz | 100 kHz | 500 kHz | 1 MHz
- Limits for counter and measured readings
- Refresh rate / averaging time for measuring mode
- 8 bytes of input data (count and status)
- 8 bytes of output data (preset count and commands)
General information | ||
---|---|---|
Order number | 600-310-7AA01 | |
Article name | 1x Counter , 5 V (RS422), 4 MHz, 32 bit | |
Scope of delivery | 1x Counter , 5 V (RS422), 4 MHz, 32 bit | |
Dimensions (DxWxH) | 110 x 14 x 73 mm | |
Weight | Approx. 70 g | |
Input voltage | 24 V DC | |
from the backplane bus | Yes | |
Sensor supply | 5V ±10 %, 190 mA | |
Current draw | ||
External | Max. 50 mA | |
Internal | Max. 86 mA | |
Power dissipation | 1 W | |
Parameter configuration length | 15 bytes | |
Number of counters | 1 | |
Counter bit depth | 32 bits | |
Input frequency | max. 1 MHz | |
Counting frequency per channel | Max. 4 MHz (for X4 evaluation) | |
Hot-swap capable | Yes | |
Ambient conditions | ||
Ambient temperature | 0 °C … +60 °C | |
Transport and storage temperature | -20 °C … +80 °C | |
Relative air humidity | 95 % r H without condensation | |
Protection rating | IP 20 | |
Certifications | CE, UL | |
UL | ||
Surrounding Air Temperature | 0 °C … +60°C | |
Pollution degree | 2 | |
CE | ||
Noise immunity | DIN EN 61000-6-2 “EMC Immunity” | |
Interference emission | DIN EN 61000-6-4 “EMC Emission” | |
Vibration and shock resistance | DIN EN 60068-2-8:2008 “Vibration”, DIN EN 60068-27:2010 “Shock“ | |
RoHS | Yes | |
REACH | Yes |
Slicni proizvodi:
Helmholz Function module – 2 x Counter Economy 24 V, 1 KHz, 32 bit
(Trenutno nema na stanju)
Helmholz Function module – 4 x Counter Economy 24 V, 1 KHz, 32 bit
(Trenutno nema na stanju)
Helmholz Function module – Energy Meter, 1 A
(Trenutno nema na stanju)
Helmholz Function module – Energy Meter, 5 A
(Trenutno nema na stanju)
Helmholz Function module – 1 x Counter 24 V, 500 KHz, 32 bit
(Trenutno nema na stanju)
Helmholz Function module – strain gauge weighing module
(Trenutno nema na stanju)