Schneider Electric Roof plate, PrismaSeT G Active, for enclosure, W600mm, IP30, with wireless Panel Server, white, RAL 9003; LVS08880D
Roof plate, PrismaSeT G Active, for enclosure, W600mm, IP30, with wireless Panel Server, white, RAL 9003...
Cena na upit
Roof plate, PrismaSeT G Active, for enclosure, W600mm, IP30, with wireless Panel Server, white, RAL 9003
Range | PrismaSeT |
---|---|
Range of product | PrismaSeT G Active |
Product or component type | Roof plate |
Range compatibility |
PrismaSeT (PrismaSeT G Active) enclosure PowerLogic (PowerLogic HeatTag) smart sensor PowerLogic (PowerLogic PowerTag) energy sensor |
Device application |
Low voltage electrical distribution Basic energy metering Preventive maintenance |
Enclosure type |
Metal enclosure Indoor enclosure |
installation description |
Wall-mounted enclosure - width 600 mm Floor-standing enclosure - width 600 mm |
Kit composition |
Wireless panel server (pre-mounted) antenna with cable 2 m wiring kit for panel server |
Alarm function |
Cable overheating Power availability |
Communication port protocol |
LoRa, connection to cloud Bluetooth, connection to mobile Wireless, connection to sensors |
Maximum number of connections | 15 |
Sensor type |
Cable overheating sensor 3 maximum Energy sensor 7 maximum |
upstream connectivity | LoRaWAN |
Transmission support medium | Radio frequency 2.4…2.4835 GHz |
Local signalling |
Voltage indication: 3 LEDs (white) LoRa status: 1 LED (green and orange) Bluetooth status: 1 LED (blue) |
Control type |
Push-button (factory reset) Push-button (reboot) |
Software designation | EcoStruxure Facility Expert |
Commissioning interface | EcoStruxure Power Commission Mobile |
Standards |
IEC 61439-1 for enclosure IEC 61439-2 for enclosure IEC 61010 for wireless panel server IEC 61326-1 for wireless panel server IEC 62974-1 for wireless panel server IEC 62443-3-3: SL1 for wireless panel server |
Product certifications | ASTA |
Electrical insulation class | Class II for wireless panel server |
---|---|
Material |
Treated sheet steel Plastic |
Protective treatment | Electrophoresis treatment and hot-polymerised polyester epoxy powder |
Surface finish |
Matt Textured |
Colour | White (RAL 9003) |
[Us] rated supply voltage | 400 V AC at 50/60 Hz, 3 phases + neutral |
Supply voltage limits | 400 V (+ 10 % - 15 %) |
Maximum supply current | 10 mA |
Power consumption in VA | 8 VA |
Overvoltage category | IV |
Location of connection |
Downstream Upstream with additional protection |
Protection type | Fuse protection integrated in power supply cable kit |
Width | 590 mm |
Height | 85 mm |
Depth | 195 mm |
Net weight | 1.8 kg |
Quantity per set | Set of 1 |
IP degree of protection |
IP30 for enclosure IP55 for wireless panel server |
---|---|
IK degree of protection | IK08 |
Pollution degree | 3 for wireless panel server |
Ambient air temperature for storage | -40…85 °C for wireless panel server |
Ambient air temperature for operation | -25…70 °C for wireless panel server |
Operating altitude | 0...2000 m for wireless panel server |
Relative humidity | 93 % at 40 °C for wireless panel server |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 9.5 cm |
Package 1 Width | 23.0 cm |
Package 1 Length | 64.0 cm |
Package 1 Weight | 2.85 kg |
Unit Type of Package 2 | P12 |
Number of Units in Package 2 | 20 |
Package 2 Height | 50.0 cm |
Package 2 Width | 80.0 cm |
Package 2 Length | 120.0 cm |
Package 2 Weight | 68.0 kg |