WEHO LPV-250-12

LED Driver power supply, LPV-250-12 , output power 250W, output voltage 12V , IP67 Features : Constant voltage design Universal AC input / Full range Withstand 300VAC...

Brand: WEHO
Product Code: LPV-250-12
Availability: Check availability

Out of stock
LED Driver power supply, LPV-250-12 , output power 250W, output voltage 12V , IP67
  • Features :
  • Constant voltage design
  • Universal AC input / Full range
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Over load / Over voltage
  • Cooling by free air convection
  • Small and compact size
  • Fully encapsulated with IP67 level (Note.7}
  • Fully isolated plastic case
  • Class Ⅱ power unit, no FG
  • Class 2 power unit
  • Pass LPS
  • Suitable for LED related fixture or appliance
  • High efficiency
(such as LED Decoration or Advertisement devices}
  • 100% full load burn-in test
  • Low cost, high reliability
  • 2 years warranty

model

LPV-250-12 LPV-250-24 LPV-250-36
output

Dc output voltage

12V 24V 36V

Output voltage tolerance

±3% ±3% ±3%

Rated output current

20A 10A 7A

Output current range

0~20A 0~10A 0~7A

Output power

240W 240W 252W

Ripple and the noise

150mVp-p 200mVp-p 200mVp-p

Dc voltage adjustable scope

±10% ±10% ±10%

Start, rise, keep time

1000ms,30ms,24ms/230VAC

input

Input voltage range

180~264VAC 47~63Hz,254~370VDC

Exchange input current

2.8A/230VAC

efficiency

82% 84% 85%

Impulse current

Cold start current 50A/230VAC

Leakage current

<3.5mA/240VAC

Protection characteristics

Overload protection

Rated output power of 105% ~ 135% start the load protection, protection way: cut off output power can be automatically after the restart, recovery

environment

Working temperature, humidity

-10℃~+60℃;20%~90%RH(Please refer to reduce the specified number load curve )

Keep temperature, humidity

-20℃~+85℃;10%~95%RH No condensation

Vibrate resistance

10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis

security

Compression sex

Input/output: 1.5 KVAC input and between to KVAC output and the earth: 1.5:0.5 KVAC

Insulation resistance

Between the input and output, the output and input: with ground: 100 M / 500 VDC Ohms

standards

Safety standards

Accord with UL1012

EMC standard

Accord with EN55022,CLASSA

other

weight

2.5kg 233*122*60mm(L*W*H)

packaging

2.5kg/9pcs/22.5kg

note

1. All the parameters in has not specified, all is in 2 3 0 V voltage input, A C rated load and 2 5 ℃ conditions measuring income value.
2. Ripple and noise voltage is in 2 0 M H z bandwidth with 1 to 2 inches oscilloscope twisted pair end and 0. 1 mu and 4 7 muon capacitance measurement when.
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products