Electronic key System EKS


Search by features
Sort products by
Brand
  • 26
Price up to
In stock
  • 0
GROUP
  • 6
  • 2
  • 6
  • 4
  • 2
  • 2
  • 1
  • 3


Electronic key System EKS


Electronic-Key-System EKS with data interface offers maximum flexibility. As the user, you specify the data structure on the Electronic-Key and define how it is to be interpreted. For this purpose, you program the processing logic in the control system to suit your needs exactly.

EUCHNER EKS Electronic-Key adapter FHM, with M8 male plug EKS-A-SFH-G30-ST150; 116118

EKS Electronic-Key adapter FHM, with M8 male plug Small design for installations where there is little space Installation in standard assembly hole Ø 22.5
-
Need to order

(Out of stock)

 
 
0,00

EUCHNER Interface adapter EKS Light FSA modular (supports all operating states) EKS-A-APRA-G08; 113645

Interface adapter EKS Light FSA modular (supports all operating states) Interface adapter with 4-bit parallel interface Use in conjunction with Electronic-Key adapter
-
Need to order

(Out of stock)

Price on request

EUCHNER Electronic-Key adapter with PROFIBUS DP interface EKS-A-IDX-G01-ST09/03; 084800

Electronic-Key adapter with PROFIBUS DP interface Electronic-Key adapter with PROFIBUS DP interface in housing G01 Read/write system Remote mounting Electronic-Key
-
Need to order

(Out of stock)

Price on request

EUCHNER Interface adapter EKS PROFINET modular version FSA ; 122353

EKS-A-AIXA-G18 Interface adapter with PROFINET IO interface read/write system Usage in conjunction with Electronic-Key adapter FHM A complete read/write station
-
Need to order

(Out of stock)

Price on request

EUCHNER ANWPG TRANSPONDER CODING; 067190

Transponder Coding (TC) Software for reading and writing CIS data carriers or EKS Electronic-Keys
-
Need to order

(Out of stock)

Price on request

EUCHNER Electronic-Key adapter with Ethernet TCP/IP interface EKS-A-IEX-G01-ST02/03; 100401

Electronic-Key adapter with Ethernet TCP/IP interface Electronic-Key adapter with TCP/IP interface in housing G01 Read/write system Remote mounting Electronic-Key
-
Need to order

(Out of stock)

Price on request

EUCHNER Electronic-Key adapter EKS Light compact (supports only operating state 0) ; 111230

Electronic-Key adapter EKS Light compact (supports only operating state 0) Electronic-Key adapter with 4-bit parallel interface Simple connection Read-only system
-
Need to order

(Out of stock)

Price on request

EUCHNER Electronic Key Manager EKM demo version ANWPG ELECTRONIC KEY MANAGER DEMO; 093320

Electronic Key Manager EKM demo version Software for key management Only local EKM client, no network support Access to key database and key database export/import
-
Need to order

(Out of stock)

Price on request

EUCHNER Electronic-Key adapter with PROFINET interface EKS-A-IIX-G01-ST02/03; 106305

Electronic-Key adapter with PROFINET interface Electronic-Key adapter with PROFINET IO interface in housing G01 Read/write system Remote mounting Electronic-Key
-
Need to order

(Out of stock)

Price on request

EUCHNER Electronic-Key adapter EKS Light compact (supports all operating states) ; 109820

EKS-A-IPL-G01-ST05/02 Electronic-Key adapter with 4-bit parallel interface Simple connection Read-only system Electronic-Key adapter and evaluation electronics in
-
Need to order

(Out of stock)

Price on request

EUCHNER Electronic-Key adapter EKS Light FSA compact (supports all operating states) ; 112207

EKS-A-IPLA-G01-ST05/04 Electronic-Key adapter with 4-bit parallel interface Simple connection Read-only system Electronic-Key adapter and evaluation electronics
-
Need to order

(Out of stock)

Price on request

EUCHNER Electronic-Key adapter with PROFINET interface FSA version ; 106306

EKS-A-IIXA-G01-ST02/03/04 Electronic-Key adapter with PROFINET IO interface read/write system Remote installation Electronic-Key adapter and electronics in one housing
-
Need to order

(Out of stock)

Price on request

EUCHNER Electronic Key Manager EKM single-user version ANWPG ELECTRONIC KEY MANAGER EINZEL; 098578

Electronic Key Manager EKM single-user version Software for key management Only local EKM client, no network support Access to key database and key database export/import
-
Need to order

(Out of stock)

Price on request

EUCHNER Electronic-Key adapter with serial interface EKS-A-ISX-G01-ST09/03; 084750

Electronic-Key adapter with serial interface Electronic-Key adapter with serial interface RS232/RS422 in housing G01 Read/write system Electronic-Key adapter and
-
Need to order

(Out of stock)

Price on request

EUCHNER Interface adapter EKS Light modular (supports only operating state 0) ; 113665

EKS-A-APB-G08 Interface adapter with 4-bit parallel interface Usage in conjunction with Electronic-Key adapter FHM A complete read-only system consists of an Electronic-Key
-
Need to order

(Out of stock)

Price on request


Page 1 od 2
Showing 1 - 15 od 26 data

Electronic key System EKS


Electronic-Key-System EKS

EKS with data interface offers maximum flexibility. As the user, you specify the data structure on the Electronic-Key and define how it is to be interpreted. For this purpose, you program the processing logic in the control system to suit your needs exactly. Numerous possible scenarios can be depicted in this way.← For example:
  • Control of certain machine functions
  • Storage of process parameters
  • Traceability of events
  • Storage of an expiry date on the Electronic-Key
  • Different access rights for multiple processes

Benefits for you

  • Safe, controlled access to your processes
  • Automatic logging on and logging off by placing the Electronic-Key
  • Variety of possible applications in all sectors due to industrial housing
  • Straightforward integration by means of various interfaces
  • Increased product quality due to controlled manufacture
  • Increased reliability of your installations and as a result lower production costs

Compact design

For the compact design, the Electronic-Key adapter and the electronics are mounted in one housing. The Electronic-Key is inserted into the Electronic-Key adapter and is held in place by a spring clip.←
  • Electronic-Key adapter and electronics in one housing
  • Very reliable retention of the Electronic-Key, even if there is heavy vibration
  • Robust housing for use in harsh environments

Version FSA

The FSA devices also have a second, redundant channel, which is generally available in the form of an additional semiconductor switching contact. This switching contact is used with functionally safe applications.

Modular design

With the modular design, the Electronic-Key adapter and electronics are mounted physically separated. Due to the separation, the Electronic-Key adapter fits in standard mounting bores with Ø 22.5 mm. The rounded shape of the Electronic-Key adapter and the FDA-approved plastic permit use in hygienically sensitive areas. With this design, the Electronic-Key is only held in front or dropped into place.←
  • Electronic-Key adapter mounted physically separated from the electronics
  • Straightforward installation in standard mounting bore Ø 22.5 mm
  • Suitable for hygienic areas
  • Very robust housing for use in extremely harsh environments

Electronic-Key-System EKS Light

EKS Light is optimized for quick, straightforward integration into a control system environment. For this purpose, the Electronic-Key has a pre-defined data structure that is evaluated directly by the read-only station.← With EKS Light, you therefore procure not just the EKS hardware, but an integrated solution for managing user groups (who is allowed to access what?) and access levels (what is the user allowed to do?).← For this purpose, the data structure on the Electronic-Key and the evaluation electronics in the read-only station form a closed system with user group identification and up to 16 access levels that can be used directly for a suitable application.← The complete evaluation logic for Electronic-Key detection is already integrated into the device and therefore does not need to be programmed into a control system.← The device first determines whether the Electronic-Key read is valid and access to the machine is authorized. If this is the case, the access level is determined and transferred to the control system via the 4-bit parallel interface. The authorization for a specific machine function must be assigned in the control system for each access level detected; the machine function is enabled in this way.


ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products