Siemens S7-1500, DQ 16x230VAC/1A ST (Triac); 6ES7522-5FH00-0AB0
SIMATIC S7-1500, digital output module DQ 16x230 V AC/1 A ST; TRIAC; 16 channels in groups of 2; 2 A per group; Substitute value: Front connector (screw terminals...
Price on request
| SIMATIC S7-1500, digital output module DQ 16x230 V AC/1 A ST; TRIAC; 16 channels in groups of 2; 2 A per group; Substitute value: Front connector (screw terminals or push-in) to be ordered separately |
| General information | |
| Product type designation | DQ 16x230VAC/1A ST (Triac) |
| HW functional status | From FS01 |
| Firmware version | V 1.2.0 |
| ● FW update possible | Yes |
| Product function | |
| ● I&M data | Yes; I&M0 to I&M3 |
| ● Isochronous mode | No |
| ● Prioritized startup | Yes |
| Engineering with | |
| ● STEP 7 TIA Portal configurable/integrated from version | V13 SP1 / - |
| ● STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| ● PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 |
| ● PROFINET from GSD version/GSD revision | V2.3 / - |
| Operating mode | |
| ● DQ | Yes |
| ● DQ with energy-saving function | No |
| ● PWM | No |
| ● Oversampling | No |
| ● MSO | Yes |
| ● Integrated operating cycle counter | Yes; FW V1.2.0 or higher |
| output voltage / header | |
| Rated value (AC) | 230 V; 120/230 V AC, 50/60 Hz |
| Power | |
| Power available from the backplane bus | 1.2 W |
| Power loss | |
| Power loss, typ. | 11.1 W |
| Digital outputs | |
| Type of digital output | Triac |
| Number of digital outputs | 16 |
| Current-sinking | Yes |
| Current-sourcing | Yes |
| Digital outputs, parameterizable | Yes |
| Short-circuit protection | No |
| ● built-in fuse | 6.3 A melting fuse, slow-blow |
| Size of motor starters according to NEMA, max. | 4 |
| Switching capacity of the outputs | |
| ● with resistive load, max. | 1 A |
| ● on lamp load, max. | 50 W |
| Output voltage | |
| ● for signal "1", min. | L1 (-1.5 V) at maximum output current; L1 (-8.5 V) at minimum output current |
| Output current | |
| ● for signal "1" rated value | 1 A |
| ● for signal "1" permissible range, min. | 10 mA |
| ● for signal "1" permissible range, max. | 15 A; max. 1 AC cycle |
| ● for signal "0" residual current, max. | 2 mA |
| Output delay with resistive load | |
| ● "0" to "1", max. | 1 AC cycle |
| ● "1" to "0", max. | 1 AC cycle |
| Parallel switching of two outputs | |
| ● for logic links | No |
| ● for uprating | No |
| ● for redundant control of a load | Yes |
| Switching frequency | |
| ● with resistive load, max. | 10 Hz |
| ● with inductive load, max. | 0.5 Hz |
| ● on lamp load, max. | 1 Hz |
| Total current of the outputs | |
| ● Current per channel, max. | 1 A; see additional description in the manual |
| ● Current per group, max. | 2 A; see additional description in the manual |
| ● Current per module, max. | 10 A; see additional description in the manual |
| Cable length | |
| ● shielded, max. | 1 000 m |
| ● unshielded, max. | 600 m |
| Interrupts/diagnostics/status information | |
| Diagnostics function | No |
| Substitute values connectable | Yes |
| Alarms | |
| ● Diagnostic alarm | No |
| ● Maintenance interrupt | Yes; maintenance alarm for switching cycle counter |
| Diagnoses | |
| ● Monitoring the supply voltage | No |
| ● Wire-break | No |
| ● Short-circuit | No |
| Diagnostics indication LED | |
| ● RUN LED | Yes; green LED |
| ● ERROR LED | Yes; red LED |
| ● Monitoring of the supply voltage (PWR-LED) | No |
| ● Channel status display | Yes; green LED |
| ● for channel diagnostics | No |
| ● for module diagnostics | Yes; red LED |
| Potential separation | |
| Potential separation channels | |
| ● between the channels | No |
| ● between the channels, in groups of | 2 |
| ● between the channels and backplane bus | Yes |
| Permissible potential difference | |
| between different circuits | 250 V AC between the channels and the backplane bus; 500 V AC between the channels |
| Isolation | |
| Isolation tested with | 3 100 V DC |
| Standards, approvals, certificates | |
| Suitable for safety functions | No |
| Ambient conditions | |
| Ambient temperature during operation | |
| ● horizontal installation, min. | 0 °C |
| ● horizontal installation, max. | 60 °C |
| ● vertical installation, min. | 0 °C |
| ● vertical installation, max. | 40 °C |
| Dimensions | |
| Width | 35 mm |
| Height | 147 mm |
| Depth | 129 mm |
| Weights | |
| Weight, approx. | 310 g |
| last modified: | 2/10/2022 |
Similar products:
Siemens S7-1500, DQ 16x24V DC/0.5A HF; 6ES7522-1BH01-0AB0
SIMATIC S7-1500, digital output module DQ16x24 V DC/0.5A HF; 16 channels in groups of 8; 4 A per group; single-channel diagnostics; substitute value: switching cycle
-

(Out of stock)
Price on request
Siemens S7-1500, DQ 16x24VDC/0.5A BA; 6ES7522-1BH10-0AA0
SIMATIC S7-1500, digital output module, DQ16xDC 24V/0.5A BA, 16 channels in groups of 8, 4 A per group; the module supports the safety-oriented shutdown of load
-

(Out of stock)
Price on request
Siemens S7-1500, DQ 8x24VDC/2A HF; 6ES7522-1BF00-0AB0
SIMATIC S7-1500, digital output module DQ 8x24 V DC/2A HF; 8 channels in groups of 8; 8 A per group; diagnostics; substitute value: 2 channels can be used for pulse
-

(Out of stock)
Price on request
Siemens S7-1500, DQ 8x230VAC/2A ST (Triac); 6ES7522-5FF00-0AB0
SIMATIC S7-1500, digital output module DQ 8x230 V AC/2 A ST; TRIAC; 8 channels in groups of 1; 2 A per group; Substitute value: Front connector (screw terminals
-

(Out of stock)
Price on request
Siemens S7-1500, DQ 32x24VDC/0.5A HF; 6ES7522-1BL01-0AB0
SIMATIC S7-1500, digital output module DQ 32x24V DC/0.5A HF; 32 channels in groups of 8; 4 A per group; single-channel diagnostics; substitute value, switching cycle
-

(Out of stock)
Price on request
Siemens S7-1500, DQ 32x24VDC/0.5A BA; 6ES7522-1BL10-0AA0
SIMATIC S7-1500, digital output module, DQ32xDC 24V/0.5A BA, 32 channels in groups of 8, 4 A per group; the module supports the safety-oriented shutdown of load
-

(Out of stock)
Price on request