| General information | |
| Product type designation | Ex-DQ 2x17.4VDC/27mA |
| Firmware version | V1.0 |
| ● FW update possible | Yes |
| usable BaseUnits | BU type X1 |
| Product function | |
| ● I&M data | Yes; I&M0 to I&M3 |
| ● Isochronous mode | No |
| Engineering with | |
| ● STEP 7 TIA Portal configurable/integrated from version | STEP 7 V16 or higher with HSP |
| ● STEP 7 configurable/integrated from version | STEP 7 V5.6 SP2 or higher |
| ● PCS 7 configurable/integrated from version | V9.1 |
| Operating mode | |
| ● DQ | Yes |
| ● MSO | Yes |
| Redundancy | |
| ● Redundancy capability | No |
| Input current | |
| Current consumption (rated value) | 80 mA; at 27 mA per channel |
| Current consumption, max. | 80 mA; at 27 mA per channel |
| output voltage / header | |
| Rated value (DC) | 17.4 V; See output characteristic in manual |
| Power loss | |
| Power loss, typ. | 1.2 W |
| Address area | |
| Address space per module | |
| ● Address space per module, max. | 1 byte; + 1 byte for QI information |
| Hardware configuration | |
| Automatic encoding | |
| ● Mechanical coding element | Yes |
| Selection of BaseUnit for connection variants | |
| ● 2-wire connection | BU type X1 |
| Digital outputs | |
| Number of digital outputs | 2 |
| Current-sinking | No |
| Current-sourcing | Yes |
| Digital outputs, parameterizable | Yes |
| Short-circuit protection | Yes |
| Open-circuit detection | Yes; capacitive loads can cause wire-break diagnostics when the channel is switched off |
| Overload protection | Yes |
| Limitation of inductive shutdown voltage to | DQ.n- (-1 V) |
| Switching capacity of the outputs | |
| ● with resistive load, max. | 27 mA; See output characteristic in manual |
| ● with inductive load, max. | 27 mA; See output characteristic in manual |
| Load resistance range | |
| ● lower limit | 480 Ω; parallel operation 240 ohm, see output characteristic in manual |
| ● upper limit | 10 kΩ; parallel operation 5 kOhm, see output characteristic in manual |
| Output current | |
| ● for signal "1" rated value | 27 mA |
| ● for signal "0" residual current, max. | 100 µA; 250 µA test current for wire break diagnostics, parallel operation 500 µA |
| Output delay with resistive load | |
| ● "0" to "1", typ. | 50 µs |
| ● "1" to "0", typ. | 100 µs |
| Parallel switching of two outputs | |
| ● for uprating | Yes |
| Switching frequency | |
| ● with resistive load, max. | 500 Hz |
| ● with inductive load, max. | 500 Hz |
| Total current of the outputs | |
| ● Current per channel, max. | 27 mA |
| ● Current per module, max. | 54 mA |
| Total current of the outputs (per module) | |
| horizontal installation | |
| — up to 70 °C, max. | 54 mA |
| vertical installation | |
| — up to 60 °C, max. | 54 mA |
| Cable length | |
| ● shielded, max. | 500 m; Ex characteristic values must be observed |
| ● unshielded, max. | 500 m; Ex characteristic values must be observed |
| Interrupts/diagnostics/status information | |
| Diagnostics function | Yes |
| Substitute values connectable | Yes |
| Alarms | |
| ● Diagnostic alarm | Yes |
| ● Maintenance interrupt | Yes |
| Diagnoses | |
Similar products:
Siemens ET 200SP, RQ CO 3x120VDC.230VAC/5A ST; 6ES7132-6HC50-0BU0
SIMATIC ET 200SP, relay module, RQ CO 3x 120V DC..230VAC/5A ST, 3 CO contacts isolated contacts, packing unit: 1 unit, suitable for BU type U0, color code CC20,
-

(Out of stock)
Price on request
Siemens ET 200SP, RQ COni 3x120VDC.230VAC/5A ST; 6ES7132-6HC70-0BU0
SIMATIC ET 200SP, relay module, RQ COni 3x120VDC..230VAC/5A ST, 3 CO contacts non-isolated contacts, packing unit: 1 unit, suitable for BU type U0, color code CC20,
-

(Out of stock)
Price on request
Siemens ET 200SP, F-RQ 1x24VDC/24..230VAC/5A ST; 6ES7136-6RA00-0BF0
SIMATIC DP, Electronics module f. ET200SP, F-RQ 1x 24 V DC/24..230VAC/5A ST, 20 mm overall width, 1 relay output (2 NO) Summation output current 5 A, load voltage
-

(Out of stock)
Price on request
Siemens ET 200SP, DQ 8x 24VDC/0,5A SINK BA, PU 1; 6ES7132-6BF61-0AA0
SIMATIC ET 200SP, Digital output module, DQ 8x 24V DC/0,5A Sink Basic, Sink output (NPN, M-switching), Packing unit: 1 piece, fits to BU-type A0, Colour Code CC01,
-

(Out of stock)
Price on request
Siemens ET 200SP, DQ 8x 24V DC/0,5A Basic, PU 1; 6ES7132-6BF01-0AA0
SIMATIC ET 200SP, Digital output module, DQ 8x 24V DC/0,5A Basic, Source output (PNP,P-switching) Packing unit: 1 piece, fits to BU-type A0, Colour Code CC02, substitute
-

(Out of stock)
Price on request
Siemens ET 200SP, DQ 4x24VDC/2A ST; 6ES7132-6BD20-0BA0
SIMATIC ET 200SP, digital output module, DQ 4x 24VDC/2A Standard, suitable for BU type A0, Color code CC02, Module diagnostics
-

(Out of stock)
Price on request