Klemsan True RMS Current Transducer CT3-AC-24 ; 600102

Klemsan True RMS Current Transducer CT3-AC-24 ; 600102

Configurable current converter CT3-AC-24. Maximum input current is 5A . 10 combinations for output signal(analog or digital, current or voltage). Supply voltage...

Brand: Klemsan
Product Code: 600102
Availability: Check availability
VAT-exclusive price: 13.190,79
VAT-inclusive price: 15.828,95
Configurable current converter CT3-AC-24. Maximum input current is 5A . 10 combinations for output signal(analog or digital, current or voltage). Supply voltage 10..36 V DC. Easy install and set. IP20 protection.
General    
  Casing Width (mm) 36
  Connections Screw terminal
Input Signal Configurable Voltage Range 0-24VAC ---
    0-36VAC ---
    0-54VAC ---
    0-80VAC ---
    0-120VAC ---
    0-170VAC ---
    0-250VAC ---
    0-400VAC ---
    0-450VAC ---
    0-500VAC ---
    0-24VDC ---
    0-54VDC ---
    0-120VDC ---
    0-250VDC ---
    0-450VDC ---
  Configurable Current Range 0-1AAC
    0-2AAC
    0-3AAC
    0-4AAC
    0-5AAC
Input Signal Frequency 40-70 Hz
  Surge Overload 20xin (100 A) for 1 sec.
  Constant Overload 10A (2x Rated IN)
  Input Impedances 49.9 Ω (burden resistor)
Output Type 0-20mA
    4-20mA
    ±20mA
    20-0mA
    20-4mA
    0-5V
    0-10V
    ±5V
    ±10V
    10-0V
  Analog Output Max. Current 24 mA
    Max. Voltage 12V
    Max. Load 10 Ω (for voltage) / 600 Ω (for current)
Supply Voltage AC ---
    DC 10-36V
Supply Frequency ---
Power Consumption DC <1.5W
  AC <4VA
General Isolation 1.5 kVrms, 3-way
  Test Voltage between Input-Output 4 kV during 1 min.
  Linearity <0.2%
  Response Time 350ms
  Ripple <80mV
  Accuracy <0.2% (full scale, 25°C)
  Temperature Coefficient 150 ppm/°C
Ambient Conditions Operating Temperature -20°C +60°C
  Storing Temperature -40°C +75°C
  Relative Humidity (No Condensation) Maks. 95%
General Protection Class IP20
  Mounting Type Panel or Rail
EMC-EMI Radiated Emissionas Test, 61000-6-2/AC:2012, 61000-6-4:2007/A1:2011
General Packing Unit 1
  Dimensions  
  Weight (g) 81
  • CT3 EN 2711018

    CT3 EN 2711018



Similar products:


Klemsan True RMS Current Transducer CT3-AC ; 600100

Configurable current converter CT3-AC. Maximum input current is 5A . 10 combinations for output signal(analog or digital, current or voltage). Supply voltage 85-264
-
Need to order

(Out of stock)

 
 
14.232,42

Klemsan Non-isolated PT100 Transducer (-50-100) ; 603860

Non-isolated PT100 transducer TT-RTD-LP 603860. Input signal PT100 sensor ( -50C - +100C) . Output analog current signal 4..20mA. Flexible and easy mounting, width
-
Need to order

(Out of stock)

 
 
6.506,05

Klemsan Non-isolated PT100 Transducer (0-100) ; 603861

Non-isolated PT100 transducer TT-RTD-LP 603861. Input signal PT100 sensor ( -0C - +100C) . Output analog current signal 4..20mA. Flexible and easy mounting, width
-
Need to order

(Out of stock)

 
 
6.506,05

Klemsan True RMS Voltage Transducer VT3-AC ; 600101

Configurable voltage converter VT3-AC. Input signal range 0-500VAC (detailed about range in teh.spec) , output signal is analog or digital, current or voltage.(10
-
Need to order

(Out of stock)

 
 
14.006,69

Klemsan True RMS Current Transducer CT3-AC ; 600100

Configurable current converter CT3-AC. Maximum input current is 5A . 10 combinations for output signal(analog or digital, current or voltage). Supply voltage 85-264
-
Need to order

(Out of stock)

 
 
14.232,42

Klemsan Configurable PT100 Transducer Ascon 321 ; 602310

Configurable PT100 Transducer Ascon 321. Input signal is a PT100(2,3,4 wires), configurable -150C-800C. 10 output signal combination(current or voltage signals)
-
Need to order

(Out of stock)

 
 
17.140,98

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 43
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products