EUCHNER Locking set MGB-L2HE-ARA-R-109946; 109946

EUCHNER Locking set MGB-L2HE-ARA-R-109946; 109946

Locking set MGB-L2HE-ARA..., (guard locking by solenoid force) without control or indicator, guard lock monitoring switched off Guard locking with guard lock monitoring...

Brand: EUCHNER
Product Code: 109946
Availability: Check availability
Price on request

Locking set MGB-L2HE-ARA..., (guard locking by solenoid force) without control or indicator, guard lock monitoring switched off

  • Guard locking with guard lock monitoring (switched off)
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • With cable entry
  • With escape release
  • Unicode

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-09_

Handle modules MGB-H-AA1A1-R-100464 (Order no. 100464)

Handle modules MGB-H-AA1A1-R-100464  (Order no. 100464)

Mechanical values and environment

Installation orientation Door hinge DIN right
Degree of protection IP65
Ambient temperature -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Product version number V3.0.0

Escape release MGB-E-A-100465 (Order no. 100465)

Escape release MGB-E-A-100465  (Order no. 100465)

Mechanical values and environment

Installation orientation any
Mechanical life 1 x 10⁶
Ambient temperature -30 ... +55 °C
Material  
Housing Die-cast zinc/stainless steel, powder-coated

Miscellaneous

Product version number V2.0.0

Locking modules MGB-L2-ARA-BA1A1-M-109945 (Order no. 109945)

Locking modules MGB-L2-ARA-BA1A1-M-109945  (Order no. 109945)

Operating and display elements

Occupancy diagram L0

Electrical connection values

Connection cross section  
(rigid/flexible) 0.13 ... 1.5 mm² 
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0.25 ... 0.75 mm²
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 0.25 ... 1.5 mm²
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time  
between FO1A and FO1B max. 10 ms
Utilization category  
DC-13 24 V 200 mA 
Risk time according to EN 60947-5-3 max. 350 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
  Solenoid control input IMP1, IMP2, IMM
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms
  Monitoring outputs OD, OT, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC 
Output current max. 50 mA
  Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B HIGH UB-2V ... UB V DC 
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current  
per safety output FO1A / FO1B 1 ... 200 mA
Test pulse duration max. 1 ms
Test pulse interval min. 100 ms
  Power supply UA
Operating voltage DC  
UA 24 V DC -15% ... +10% 
Current consumption  
IUA max. 375 mA 
  Power supply UB
Operating voltage DC  
UB 24 V DC -15% ... +10% 
Current consumption  
IUB max. 80 mA 

Mechanical values and environment

Connection type Cable entries M20x1.5
Installation orientation Door hinge DIN right
Switching frequency 0.25 Hz
Mechanical life  
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
  1 x 10⁶
Degree of protection IP65
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
  Monitoring of guard locking and the guard position
Category 4
Performance Level PL e
PFH

Similar products:


EUCHNER Locking module MGB-L1-ARA-AJ4A1-M-R-122235; 122235

Locking module MGB-L1-ARA..., (guard locking by spring force) with 3 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L1-ARA-AK1A1-M-R-120990; 120990

Locking module MGB-L1-ARA..., (guard locking by spring force) with 1 pushbutton Guard locking with guard lock monitoring Can be connected in series with other AR
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L1-ARA-AM3A1-M-R-121234; 121234

Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1H-ARA-R-121235; 121235

Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L2-ARA-BM3A1-M-R-121222; 121222

Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop Guard locking with guard lock monitoring (switched off) Can be
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking module MGB-L1-ARA-AB8A1-M-110219; 110219

Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products