EUCHNER Locking module MGB-L1-APA-AA6A1-S3-R-110585; 110585

EUCHNER Locking module MGB-L1-APA-AA6A1-S3-R-110585; 110585

Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, incl. label carrier, M12 for enabling switch Guard locking with guard lock monitoring...

Brand: EUCHNER
Product Code: 110585
Availability: Check availability
Price on request

Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, incl. label carrier, M12 for enabling switch

  • Guard locking with guard lock monitoring
  • 3 pushbuttons (illuminated, wh, ye, bu)
  • incl. adhesive labels
  • With cable entry
  • With plug connector M12 for enabling switch
  • Unicode

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-09_

Operating and display elements

Occupancy diagram L1
Item Extras Color Designation1 Number LED Note slide-in label Slide-in label Version Switching element
2   white           Illuminated pushbutton 1NO
3   Yellow           Illuminated pushbutton 1NO
4   Blue           Illuminated pushbutton 1NO

Electrical connection values

Connection cross section  
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 0.25 ... 1.5 mm²
(rigid/flexible) 0.13 ... 1.5 mm² 
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0.25 ... 0.75 mm²
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time  
between FO1A and FO1B max. 10 ms
Utilization category  
DC-13 24V 200mA 
Risk time according to EN 60947-5-3 max. 350 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
  Solenoid control input IMP1, IMP2, IMM
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms
  Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage UA V
Switching current 1 ... 10 mA
LED power supply 24 V DC
  Monitoring outputs OD, OT, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC 
Output current max. 50 mA
  Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-2V ... UB V DC 
Output current  
per safety output FO1A / FO1B 1 ... 200 mA
Test pulse duration max. 0.3 ms
Test pulse interval min. 100 ms
  Power supply UA
Operating voltage DC  
UA 24 V DC -15% ... +10% 
Current consumption  
IUA max. 375 mA 
  Power supply UB
Operating voltage DC  
UB 24 V DC -15% ... +10% 
Current consumption  
IUB max. 80 mA 

Mechanical values and environment

Connection type  
  Cable entries M20x1.5
  Plug connector SFF5 
Installation orientation Door hinge DIN right
Switching frequency 0.25 Hz
Mechanical life  
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
  1 x 10⁶
Degree of protection IP65
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
  Control of guard locking
Category 4
Performance Level PL e
PFHD 2.8 x 10

Similar products:


EUCHNER Locking module MGB-L1-APA-AP4A1-M-R-137326; 137326

Locking module MGB-L1-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1H-APA-R-110587; 110587

Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, incl. label carrier, M12 for enabling switch Guard locking with guard lock monitoring
-
Need to order

(Out of stock)

Price on request

EUCHNER Locking set MGB-L1H-APA-R-115178; 115178

Locking set MGB-L1H-APA... (guard locking by spring force) with 2 pushbuttons, emergency stop Guard locking with guard lock monitoring Emergency stop according to
-
Need to order

(Out of stock)

Price on request

EUCHNER Interlocking set MGB-L0H-ARA-R-105779; 105779

Interlocking set MGB-L0H-ARA..., with 2 pushbuttons, emergency stop Interlocking (without guard locking) Can be connected in series with other AR devices (e.g. CES-AR
-
Need to order

(Out of stock)

Price on request

EUCHNER Interlocking set MGB-L0H-APA-R-110550; 110550

Auxiliary release Connection via cable entry, M20 x 1.5 or plug connector Plug connector connection, either HC26, M23 (RC18) or M12, 12-pin Operation of guard locking
-
Need to order

(Out of stock)

Price on request

EUCHNER Interlocking set MGB-L0HE-APA-R-112600; 112600

Interlocking set MGB-L0HE-APA..., without controls or indicators, RC18, on mounting plates Locking (without guard locking) With plug connector RC18 Mounted on mounting
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products