Schneider Electric Zaštitna jedinica MicroLogic 2.2 G za ComPacT NSX 100/160/250 prekidače, elektronska, struja 100 A, 3P 3d;C1032G100

Schneider Electric Zaštitna jedinica MicroLogic 2.2 G za ComPacT NSX 100/160/250 prekidače, elektronska, struja 100 A, 3P 3d;C1032G100

Trip unit MicroLogic 2.2G, ComPacT NSX100/160/250, 3 poles, electronic basic protections, generator protection, 100A...

Brand: Schneider Electric
Product Code: C1032G100
Availability: Check availability
VAT-exclusive price: 19.225,00
VAT-inclusive price: 23.070,00

Trip unit MicroLogic 2.2G, ComPacT NSX100/160/250, 3 poles, electronic basic protections, generator protection, 100A


Main
range ComPacT new generation
range of product ComPacT NSX100...250 new generation
product or component type Trip unit
trip unit name Micrologic 2.2 G
trip unit technology Electronic
range compatibility ComPacT new generation NSX100
ComPacT new generation NSX160
ComPacT new generation NSX250
device application Generator
poles description 3P
protected poles description 3D
trip unit protection functions LSoI
protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating 100 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
network type AC
network frequency 50/60 Hz
Circuit breaker mounting mode Fixed
Complementary
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40...100 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 15 s at 1.5 x Ir
0.35 s at 7.2 x Ir
0.5 s at 6 x Ir
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable
[Isd] Short-time protection pick-up adjustment range 1.5...9 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1500 A
earth-leakage protection Without
zone selective interlocking ZSI Without
local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Environment
standards EN/IEC 60947-2
electrical shock protection class Class II
pollution degree 3 conforming to IEC 60947-1
IP degree of protection IP40 conforming to IEC 60529
ambient air temperature for operation -25…70 °C
ambient air temperature for storage -50…85 °C
 
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 432.0 g
Package 1 Height 6.5 cm
Package 1 width 9.5 cm
Package 1 Length 11.0 cm
Unit Type of Package 2 S03
Number of Units in Package 2 24
Package 2 Weight 10.828 kg
Package 2 Height 30.0 cm
Package 2 width 30.0 cm
Package 2 Length 40.0 cm

Main
range ComPacT new generation
range of product ComPacT NSX100...250 new generation
product or component type Trip unit
trip unit name Micrologic 2.2 G
trip unit technology Electronic
range compatibility ComPacT new generation NSX100
ComPacT new generation NSX160
ComPacT new generation NSX250
device application Generator
poles description 3P
protected poles description 3D
trip unit protection functions LSoI
protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating 100 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
network type AC
network frequency 50/60 Hz
Circuit breaker mounting mode Fixed
Complementary
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40...100 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 15 s at 1.5 x Ir
0.35 s at 7.2 x Ir
0.5 s at 6 x Ir
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable
[Isd] Short-time protection pick-up adjustment range 1.5...9 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1500 A
earth-leakage protection Without
zone selective interlocking ZSI Without
local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Environment
standards EN/IEC 60947-2
electrical shock protection class Class II
pollution degree 3 conforming to IEC 60947-1
IP degree of protection IP40 conforming to IEC 60529
ambient air temperature for operation -25…70 °C
ambient air temperature for storage -50…85 °C
 
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 432.0 g
Package 1 Height 6.5 cm

Similar products:


Schneider Electric prekidač ComPacT NSX100M AC/DC, 40 kA na 240 VAC, TMD zaštitna jedinica 40 A, 1P 1d;C10M1TM040

Circuit breaker, ComPacT NSX100M AC/DC, 40kA/240VAC, 1 pole, TMD trip unit 40A
-
Need to order

(Out of stock)

 
 
18.308,00

Schneider Electric prekidač ComPacT NSX160F AC/DC, 18 kA na 415 VAC, TMD zaštitna jedinica 125 A, 2P 2d;C16F2TM125

Circuit breaker, ComPacT NSX160F AC/DC, 18kA/415VAC, 2 poles, TMD trip unit 125A
-
Need to order

(Out of stock)

 
 
23.981,00

Schneider Electric prekidač osnovni model, ComPacT NSX100S DC, 100 kA na 750 VDC, 100 A, bez zaštitne jedinice, 4P;C10S4D

Circuit breaker basic frame, ComPacT NSX100S DC, 100kA/750VDC, 4 poles, 100A frame rating, without trip unit
-
Need to order

(Out of stock)

 
 
24.764,00

Schneider Electric prekidač ComPacT NSX80 DC PV, 80 A, 1000 V, TM-D zaštitna jedinica, 4P;C10F4TM080D1

Circuit breaker, ComPacT NSX80 DC PV, 10kA/1000VDC, 4 poles, TM-DC PV trip unit 80A
-
Need to order

(Out of stock)

 
 
25.869,98

Schneider Electric prekidač ComPacT NSX160M AC/DC, 25 kA na 415 VAC, TMD zaštitna jedinica 125 A, 2P 2d;C16M2TM125

Circuit breaker, ComPacT NSX160M AC/DC, 25kA/415VAC, 2 poles, TMD trip unit 125A
-
Need to order

(Out of stock)

 
 
29.812,00

Schneider Electric prekidač ComPacT NSX400S DC, 100 kA na 750 VDC, TM-DC zaštitna jedinica, 400 A struja, 4P;C40S4TM400D

Circuit breaker, ComPacT NSX400S DC, 100kA/750VDC, 4 poles, TM-DC trip unit 400A
-
Need to order

(Out of stock)

 
 
196.968,00

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products