Schneider Electric Strujni kontrolni relej 0.15A…15A, 2 C/O ; RM35JA32MR

Schneider Electric Strujni kontrolni relej 0.15A…15A, 2 C/O ; RM35JA32MR

Current control relay 0.15A…15A, 2 C/O...

Brand: Schneider Electric
Product Code: RM35JA32MR
Availability: Check availability
VAT-exclusive price: 15.746,00
VAT-inclusive price: 18.895,20

Current control relay 0.15A…15A, 2 C/O

Main
range of product
Zelio Control
 
product or component type
Modular measurement and control relays
 
relay type
Current control relay
 
relay name
RM35JA
 
relay monitored parameters
Overcurrent or undercurrent in window mode
Overcurrent or undercurrent detection
 
time delay type
Adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
 
switching capacity in VA
2000 VA
 
measurement range
0.15...1.5 A E1-M terminals
0.5...5 A E2-M terminals
1.5...15 A E3-M terminals
150 mA...15 A current AC/DC 50/60 Hz
 
Complementary
reset time
1500 ms at maximum voltage
 
maximum switching voltage
250 V AC
 
minimum switching current
10 mA at 5 V DC
 
maximum switching current
8 A AC
 
[Us] rated supply voltage
24...240 V AC/DC 50/60 Hz +/- 10 %
 
supply voltage limits
20.4…264 V AC/DC
 
operating limits
- 15 % + 10 % Un
 
power consumption in VA
3.5 VA AC
 
maximum power consumption in W
1.5 W DC
 
resistance across terminals
0.005 Ohm at E3-M terminals
0.015 Ohm at E2-M terminals
0.05 Ohm at E1-M terminals
 
output contacts
2 C/O
 
nominal output current
8 A
 
internal input resistance
0.015 Ohm
0.005 Ohm
0.05 Ohm
 
setting accuracy of the switching threshold
+/- 10 % of the full scale
 
switching threshold drift
<= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range
 
setting accuracy of time delay
10 %
 
time delay drift
<= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range
 
hysteresis
5…50 % adjustable of threshold setting for overcurrent or undercurrent detection
3 % fixed of full scale for window mode
 
run-up delay at power-up
0.3 s
 
maximum measuring cycle
100 ms measurement cycle as true rms value
 
repeat accuracy
+/- 0.5 % for input and measurement circuit
+/- 2 % for time delay
 
measurement error
< 1 % over the whole range with voltage variation
0.05 %/°C with temperature variation
 
response time
<= 500 ms (on crossing the threshold)
 
threshold setting
10...100 %
 
overvoltage category
III conforming to IEC 60664-1
III conforming to UL 508
 
insulation resistance
> 100 MOhm at 500 V DC conforming to IEC 60255-27
 
insulation
Between supply and measurement
 
mounting position
Any position
 
connections - terminals
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
 
tightening torque
0.6…1 N.m conforming to IEC 60947-1
 
housing material
Self-extinguishing plastic
 
status LED
LED (yellow)relay ON:
LED (green)power ON:
 
mounting support
35 mm DIN rail conforming to EN/IEC 60715
 
electrical durability
100000 cycles
 
mechanical durability
10000000 cycles
 
utilisation category
AC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
AC-1 conforming to IEC 60947-4-1
DC-1 conforming to IEC 60947-4-1
 
safety reliability data
MTTFd = 296.8 years
B10d = 270000
 
contacts material
Cadmium free
 
width
35 mm
 
net weight
0.12 kg
 
Environment
immunity to microbreaks
50 ms
 
electromagnetic compatibility
Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1
Immunity for industrial environments conforming to EN/IEC 61000-6-2
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4
Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
Conducted and radiated emissions class B group 1 conforming to CISPR 11
Conducted and radiated emissions class B conforming to CISPR 22
Emission standard for residential, commercial and light-industrial environments (except radiated emission) conforming to EN/IEC 61000-6-3
 
standards
EN/IEC 60255-1
 
product certifications
CE
GL
CCC
EAC
RCM
China RoHS
UL
CSA
 
ambient air temperature for storage
-40…70 °C
 
ambient air temperature for operation
-20…50 °C at 60 Hz
-20…60 °C at 50 Hz AC/DC
 
environmental characteristic
3K3 C
 
relative humidity
93…97 % at 25…55 °C conforming to IEC 60068-2-30
 
vibration resistance
0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
 
shock resistance
15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
 
IP degree of protection
IP20 (terminals) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
IP30 (housing) conforming to IEC 60529
 
pollution degree
3 conforming to IEC 60664-1
3 conforming to UL 508
 
dielectric test voltage
2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
 
Packing Units
Package 1 Weight
0.120 kg
 
Package 1 Height
0.780 dm
 
Package 1 width
0.450 dm
 
Package 1 Length
0.950 dm
 
Offer Sustainability
Sustainable offer status
Green Premium product
 
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
 
Mercury free
Yes
 
RoHS exemption information  
China RoHS Regulation  
Environmental Disclosure  
Circularity Profile  
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • Zelio Control RM35JA32MR

    Zelio Control RM35JA32MR



Similar products:


Schneider Electric relej za kontrolu napona RM17-U - opseg 183..528 V AC ; RM17UB310

Modular 3-phase voltage control relay, 5 A, 1 CO, 208...480 V AC
-
Need to order

(Out of stock)

 
 
5.453,00

Schneider Electric Relej za kontrolu struje RM17-J - opseg: 2..20 A ; RM17JC00MW

Modular current control relay, 8 A, 1 CO, overcurrent function, 250 V AC/DC
-
Need to order

(Out of stock)

 
 
8.912,00

Schneider Electric Prekostrujni relej 4 mA…1A, 2 C/O ; RM22JA21MR

Overcurrent control relay 4mA…1A, 2 C/O
-
Need to order

(Out of stock)

 
 
11.240,00

Schneider Electric Relej za kontrolu struje RM35-J - opseg 2..500 mA;RM35JA31MW

Harmony, Modular 1-phase current control relay, 5 A, 2 CO, 2…500 mA, , 24…240 V AC/DC
-
Need to order

(Out of stock)

 
 
14.169,00

Schneider Electric Relej za kontrolu jačine struje RM35-J - opseg 0.15..1.5 A ; RM35JA32MW

Modular 1-phase current control relay, 5 A, 2 CO, 0.15…15 A,, 24…240 V AC/DC
-
Need to order

(Out of stock)

 
 
14.169,00

Schneider Electric Strujni kontrolni relej 0.15A…15A, 2 C/O ; RM35JA32MT

Current control relay 0.15A…15A, 2 C/O
-
Need to order

(Out of stock)

 
 
16.239,00

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1