WEHO S-35-24

Features: High efficiency, high reliability and low cost Switch input voltage range choice 100% full load and machine test Protection characteristics: short circuit/overload...

Brand: WEHO
Product Code: S-35-24
Availability: Check availability

Out of stock
Features:
High efficiency, high reliability and low cost
Switch input voltage range choice
100% full load and machine test
Protection characteristics: short circuit/overload
Air cooling
Working frequency 37 KHz
Two years warranty
Size: 129*98*38mm (L * W * H)

Model

S-35-5

S-35-9

S-35-12

S-35-15

S-35-24

OUTPUT

Dc output voltage

5V

9V

12V

15V

24V

Output voltage tolerance

±2%

±1%

±1%

±1%

±1%

Rated output current

7A

3.6A

3A

2.4A

1.5A

Output current range

0-7A

0-3.6A

0-3A

0-2.4A

0-1.5A

Output power

35W

32.4W

36W

36W

36W

Ripple and the noise

75mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

Dc voltage adjustable scope

+10,-5%

±10%

±10%

±10%

±10%

Start, rise, keep time

200ms,100ms,30ms Loaded with

INPUT

Input voltage range

85~132 VAC/170~264VAC 47~63 Hz;选择 240~370VDC

Exchange input current

0.8 A/115 V 0.45A/ 230 V

efficiency

70%

72%

76%

78%

78%

Impulse current

Cold start current 18A/115V 36A/230V

Leakage current

<2mA/240VAC

PROTECTION

Overload protection

110%~160%

Protection way: current limiting, automatic recovery

ENVIRONMENT

Working temperature, humidity

-10℃~+60℃;20%~90 %RH

Keep temperature, humidity

-20℃~+85℃;10%~95 %RH

Vibrate resistance

10~500Hz,2G 10min./1 cycle time, 60 minutes, the axis

SAFETY

Compression sex

Between input and output
:1.5KVAC Input and to
:1.5KVAC Output and to
:0.5KVAC

Insulation resistance

Between the input and output, the input and output, and the earth
: 100M Ohms/500VDC

STANDARD

Safety standards

Accord with
UL1012

EMC standards

Design refer to FCC Part15 J Conduction Class B

OTHERS

weight

0.4Kg

packaging

45pcs/18.8Kg/1.22CUFT

NOTE

1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value.
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.
4. Specific output current see output drop forehead curve.

Similar products:


Schneider Electric prekidač Compact NSXm 125A 3P 25kA na 380/415V(IEC), EverLink stopica; LV426208

circuit breaker ComPact NSXm B (25 kA at 415 VAC), 3P 3d, 125 A rating TMD trip unit, EverLink connectors
-
Need to order

(Out of stock)

Price on request

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products