Siemens ET 200SP HA, EX-AI 2xI 2-WIRE HART; 6DL1134-6TB00-0HX1
SIMATIC ET 200SP HA, ET 200SP, analog ex-i HART input module, Ex-AI 2xI 2-Wire HART, suitable for BaseUnit type X1, channel diagnostics, 16bit, +/-0.3%...
Price on request
| SIMATIC ET 200SP HA, ET 200SP, analog ex-i HART input module, Ex-AI 2xI 2-Wire HART, suitable for BaseUnit type X1, channel diagnostics, 16bit, +/-0.3% |
| General information | |
| Product type designation | Ex-AI 2xI 2-wire HART |
| Firmware version | V1.0 |
| ● FW update possible | Yes |
| usable BaseUnits | BU type X1 |
| Product function | |
| ● I&M data | Yes; I&M0 to I&M3 |
| ● Isochronous mode | No |
| Engineering with | |
| ● STEP 7 TIA Portal configurable/integrated from version | STEP 7 V16 or higher with HSP |
| ● STEP 7 configurable/integrated from version | STEP 7 V5.6 SP2 or higher |
| ● PCS 7 configurable/integrated from version | V9.1 |
| Operating mode | |
| ● MSI | Yes |
| Redundancy | |
| ● Redundancy capability | No |
| CiR - Configuration in RUN | |
| Reparameterization possible in RUN | Yes |
| Input current | |
| Current consumption (rated value) | 74 mA |
| Current consumption, max. | 92 mA; Peak load (all channels in short-circuit) |
| Encoder supply | |
| 24 V encoder supply | |
| ● 24 V | Yes |
| ● Short-circuit protection | Yes; Electronic disconnection in case of short-circuit, current limitation from 27 mA |
| ● Output current per channel, max. | 28 mA |
| Power loss | |
| Power loss, typ. | 1.2 W |
| Address area | |
| Address space per module | |
| ● Address space per module, max. | 4 byte; + 0/1 byte for QI information |
| ● Address space per module with HART, max. | 24 byte; + 0/1 byte for QI information |
| ● Address space per module with MultiHART, max. | 11 byte; + 0/1 byte for QI information |
| Hardware configuration | |
| Automatic encoding | |
| ● Mechanical coding element | Yes |
| Selection of BaseUnit for connection variants | |
| ● 2-wire connection | BU type X1 |
| Analog inputs | |
| Number of analog inputs | 2; Differential inputs |
| ● For current measurement | 2 |
| Cycle time (all channels), min. | 3 ms |
| Input ranges (rated values), currents | |
| ● 0 to 20 mA | Yes |
| ● 4 mA to 20 mA | Yes; 15 bit + sign |
| — Input resistance (4 mA to 20 mA) | 400 Ω; At 20 mA input current |
| Cable length | |
| ● shielded, max. | 500 m; Ex characteristic values must be observed |
| ● unshielded, max. | 300 m; Ex characteristic values must be observed |
| Analog value generation for the inputs | |
| Measurement principle | integrating (Sigma-Delta) |
| Integration and conversion time/resolution per channel | |
| ● Resolution with overrange (bit including sign), max. | 16 bit |
| ● Integration time, parameterizable | Yes; channel by channel |
| ● Interference voltage suppression for interference frequency f1 in Hz | 10 / 50 / 60 Hz |
| Smoothing of measured values | |
| ● Number of smoothing levels | 4; None; 4/8/16 times |
| ● parameterizable | Yes |
| Encoder | |
| Connection of signal encoders | |
| ● for current measurement as 2-wire transducer | Yes |
| — Burden of 2-wire transmitter, max. | 750 Ω; At 20 mA input current |
| Errors/accuracies | |
| Linearity error (relative to input range), (+/-) | 0.01 % |
| Temperature error (relative to input range), (+/-) | 0.005 %/K |
| Crosstalk between the inputs, min. | 60 dB |
| Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.05 % |
| Operational error limit in overall temperature range | |
| ● Current, relative to input range, (+/-) | 0.3 % |
| Basic error limit (operational limit at 25 °C) | |
| ● Current, relative to input range, (+/-) | 0.2 % |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | |
| ● Series mode interference (peak value of interference < rated value of input range), min. | 60 dB |
| Protocols | |
| HART protocol | Yes |
Similar products:
Siemens ET 200SP, AI 2xU Standard, PU 1; 6ES7134-6FB00-0BA1
SIMATIC ET 200SP, Analog input module, AI 2xU Standard Pack quantity: 1 unit, suitable for BU type A0, A1, Color code CC00, Module diagnostics, 16 bit
-

(Out of stock)
Price on request
Siemens ET 200SP AI 2 X U/I 2-, 4-Wire HS; 6ES7134-6HB00-0DA1
SIMATIC ET 200SP, Analog input module, AI 2x U/I 2-.4-wire High Speed, suitable for BU type A0, A1, Color code CC00, channel diagnostics, 16 bit, +/-0.3%
-

(Out of stock)
Price on request
Siemens ET 200SP AI Energy Meter CT ST; 6ES7134-6PA01-0BU0
SIMATIC ET 200SP, analog input module, AI Energy Meter CT ST, for 1A or 5A current transformer, suitable for BU type U0, channel diagnostics
-

(Out of stock)
Price on request
Siemens ACCESSORY FOR 3NJ6; 3NJ6920-3BE21
accessory for Switch disconnector with fuses In-line design, pluggable current transformer 150/5 A, Cl. 1, 1.5 VA
-

(Out of stock)
Price on request