Trip unit MicroLogic 6.2EM, ComPacT NSX160/250, 3 poles, basic and ground fault protections, motor, energy meter, 150A
range | ComPacT new generation |
---|---|
range of product | ComPacT NSX100...250 new generation |
product or component type | Trip unit |
trip unit name | Micrologic 6.2 E-M |
trip unit technology | Electronic |
range compatibility |
ComPacT new generation NSX160 ComPacT new generation NSX250 |
device application | Motor |
poles description | 3P |
protected poles description | 3D |
trip unit protection functions | LSIG |
protection type |
L : for overload protection (long time) S : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection G : for ground fault protection |
Trip unit rating | 150 A at 65 °C |
[Ue] rated operational voltage | 690 V AC 50/60 Hz |
network type | AC |
network frequency | 50/60 Hz |
Circuit breaker mounting mode | Fixed |
motor tripping class |
10 30 5 20 |
---|---|
complementary motor protection |
Protracted starting time Stalled rotor Current unbalance Underload |
Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
[Ir] long-time protection pick-up adjustment range | 70...150 A |
Long-time protection delay adjustment type tr | Adjustable |
[tr] long-time protection delay adjustment range |
120 s at 1.5 x Ir for trip class 5 6.5 s at 6 x Ir for trip class 5 5 s at 7.2 x Ir for trip class 5 240 s at 1.5 x Ir for trip class 10 13.5 s at 6 x Ir for trip class 10 10 s at 7.2 x Ir for trip class 10 480 s at 1.5 x Ir for trip class 20 26 s at 6 x Ir for trip class 20 20 s at 7.2 x Ir for trip class 20 720 s at 1.5 x Ir for trip class 30 38 s at 6 x Ir for trip class 30 30 s at 7.2 x Ir for trip class 30 |
thermal memory | 20 minutes before and after tripping |
Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
[Isd] Short-time protection pick-up adjustment range | 5...13 x Ir |
Short-time protection delay adjustment type tsd | Fixed |
Instantaneous protection pick-up adjustment type Ii | Fixed |
[Ii] instantaneous protection pick-up adjustment range | 2250 A |
Ground-fault protection pick-up adjustment type Ig | Adjustable |
[Ig] ground-fault protection pick-up adjustment range |
0.2...1 x In Ig enable on/off |
Ground-fault protection time delay adjustment type tg | Adjustable |
[tg] ground-fault protection time delay adjustment range | 0…0.4 s |
earth-leakage protection | Without |
zone selective interlocking ZSI | With |
local signalling |
Flashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point |
display type | LCD display |
type of measurement | Energy meter |
communication of data |
Energy metering Protection and alarm settings Time-stamped histories and event tables Instantaneous and demand values Maintenance indicators Demand current and power Power quality Maximeters/minimeters |
electrical data recording | Maintenance indicators |
standards | EN/IEC 60947-2 |
---|---|
electrical shock protection class | Class II |
pollution degree | 3 conforming to IEC 60947-1 |
IP degree of protection | IP40 conforming to IEC 60529 |
ambient air temperature for operation | -25…70 °C |
ambient air temperature for storage | -40…85 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 538.0 g |
Package 1 Height | 9.5 cm |
Package 1 width | 11.0 cm |
Package 1 Length | 15.0 cm |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 11 |
Package 2 Weight | 6.306 kg |
Package 2 Height | 30.0 cm |
Package 2 width | 30.0 cm |
Package 2 Length | 40.0 cm |