Trip unit MicroLogic Vigi 4.3AL, ComPacT NSX630, 4 poles, electronic basic protections, earth leakage alarm, 570A


Main
range ComPacT new generation
range of product ComPacT NSX400...630 new generation
product or component type Trip unit
trip unit name Micrologic 4.3 AL
trip unit technology Electronic
range compatibility ComPacT new generation NSX630
device application Distribution
poles description 4P
protected poles description 3D + N/2
4D
3D
neutral position Left
trip unit protection functions LSoI
protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating 570 A at 40 °C
[Ue] rated operational voltage 440 V AC 50/60 Hz
network type AC
network frequency 50/60 Hz
Circuit breaker mounting mode Fixed
Complementary
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 250...570 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 11 s at 7.2 x Ir
16 s at 6 x Ir
400 s at 1.5 x Ir
Neutral protection settings 0.5 x Ir (3D + N/2)
1 x Ir (4D)
No protection (3D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 6900 A
earth-leakage protection Integrated
earth-leakage protection class Class A
Earth-leakage protection sensitity adjustment type IΔn Adjustable
[IΔn] earth-leakage protection sensitivity adjustment range 0.3 A
0.5 A
1 A
3 A
5 A
10 A
Earth-leakage protection specific mode OFF using the IΔn rotary switch
Earth-leakage protection time delay adjustement type Δt Adjustable
[Δt] Earth-leakage protection time delay adjustment range 0 ms
60 ms
150 ms
500 ms
1 s
zone selective interlocking ZSI Without
local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Color indicator (yellow) for residual current
Environment
standards EN/IEC 60947-2
electrical shock protection class Class II
pollution degree 3 conforming to IEC 60947-1
IP degree of protection IP40 conforming to IEC 60529
ambient air temperature for operation -25…70 °C
ambient air temperature for storage -50…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 5.898 kg
Package 1 Height 14.5 cm
Package 1 width 20.0 cm
Package 1 Length 29.5 cm
Unit Type of Package 2 S03
Number of Units in Package 2 2
Package 2 Weight 12.3 kg
Package 2 Height 30.0 cm
Package 2 width 30.0 cm
Package 2 Length 40.0 cm
Unit Type of Package 3 P12
Number of Units in Package 3 28
Package 3 Weight 181.0 kg
Package 3 Height 45.0 cm
Package 3 width 80.0 cm
Package 3 Length 120.0 cm

Main
range ComPacT new generation
range of product ComPacT NSX400...630 new generation
product or component type Trip unit
trip unit name Micrologic 4.3 AL
trip unit technology Electronic
range compatibility ComPacT new generation NSX630
device application Distribution
poles description 4P
protected poles description 3D + N/2
4D
3D
neutral position Left
trip unit protection functions LSoI
protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating 570 A at 40 °C
[Ue] rated operational voltage 440 V AC 50/60 Hz
network type AC
network frequency 50/60 Hz
Circuit breaker mounting mode Fixed

Similar products:


Schneider Electric prekidač ComPacT NSX100F AC/DC, 18 kA na 415 VAC, TMD zaštitna jedinica 63 A, 2P 2d;C10F2TM063

Circuit breaker, ComPacT NSX100F AC/DC, 18kA/415VAC, 2 poles, TMD trip unit 63A
-
Need to order

(Out of stock)

 
 
16.693,00

Schneider Electric prekidač ComPacT NSX100M AC/DC, 40 kA na 240 VAC, TMD zaštitna jedinica 20 A, 1P 1d;C10M1TM020

Circuit breaker, ComPacT NSX100M AC/DC, 40kA/240VAC, 1 pole, TMD trip unit 20A
-
Need to order

(Out of stock)

 
 
18.308,00

Schneider Electric prekidač ComPacT NSX100M AC/DC, 25 kA na 415 VAC, TMD zaštitna jedinica 63 A, 2P 2d;C10M2TM063

Circuit breaker, ComPacT NSX100M AC/DC, 25kA/415VAC, 2 poles, TMD trip unit 63A
-
Need to order

(Out of stock)

 
 
19.196,00

Schneider Electric prekidač osnovni model, ComPacT NSX160F DC, 36 kA na 750 VDC, 160 A, bez zaštitne jedinice, 3P;C16F3D

Circuit breaker basic frame, ComPacT NSX160F DC, 36kA/750VDC, 3 poles, 160A frame rating, without trip unit
-
Need to order

(Out of stock)

 
 
25.526,00

Schneider Electric prekidač ComPacT NSX200 DC PV, 200 A, 1000 VDC, TM-D zaštitna jedinica, 4P;C25F4TM200D1

Circuit breaker, ComPacT NSX200 DC PV, 10kA/1000VDC, 4 poles, TM-DC PV trip unit 200A
-
Need to order

(Out of stock)

 
 
50.806,18

Schneider Electric prekidač, ComPacT NSX630 TM-DC, 2P, 630 A, 50 kA na 600 VDC, bez neizolovanog kablovskog priključka;C1BN2TM630D

Circuit breaker, ComPacT NSX1200N DC, 50kA/600VDC, 2 poles, TM-DC trip unit 630A
-
Need to order

(Out of stock)

 
 
204.310,00

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products
Complementary
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 250...570 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 11 s at 7.2 x Ir
16 s at 6 x Ir
400 s at 1.5 x Ir
Neutral protection settings 0.5 x Ir (3D + N/2)
1 x Ir (4D)
No protection (3D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 6900 A