Schneider Electric TeSys GS - switch-disconnector fuse - 4 P - 125 A - NFC 22 x 58 mm;GS1KD4
TeSys GS - switch-disconnector fuse - 4 P - 125 A - NFC 22 x 58 mm...
Price on request
TeSys GS - switch-disconnector fuse - 4 P - 125 A - NFC 22 x 58 mm
range | TeSys |
---|---|
product name | TeSys GS |
device short name | GS1 K |
product or component type | Switch-disconnector-fuse |
device application | Protection |
poles description | 4P |
protected poles description | 4t |
contacts type and composition | 4 NO |
[Ith] conventional free air thermal current | 125 A (at 40 °C) |
[Ie] rated operational current |
100 A at 440 V 2 poles in series per phase DC-23A 100 A at 440 V 2 poles in series per phase DC-23B 100 A at 690 V with terminal cover AC-23A 100 A at 690 V with terminal cover AC-23B 125 A at 400 V AC-23A 125 A at 400 V AC-23B 125 A at 500 V AC-23A 125 A at 500 V AC-23B |
fuse type | NFC |
fuse size | 22 x 58 mm |
network type |
DC AC |
network frequency | 50/60 Hz |
type of operating handle | Direct right side |
---|---|
mounting support | Plate |
[Ui] rated insulation voltage | 750 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 8 kV |
rated operational power in W |
90 kW at 690 V 63 kW at 400 V 90 kW at 500 V |
making capacity | 1250 A at 400 V AC-23B |
[Icm] rated short-circuit making capacity | 100 kA at 400 V with protection by gG fuses |
breaking capacity | 1000 A at 400 V (AC-23B) |
short-circuit withstand | 20 kA |
mechanical durability | 10000 cycles |
electrical durability |
1000 cycles AC-23A 1000 cycles AC-23B |
connections - terminals |
Power circuit: bars Power circuit: lugs-ring terminals35…95 mm² flexible |
tightening torque |
Power circuit: 12 N.m - on bars Power circuit: 12 N.m - on lugs-ring terminals |
standards | IEC 60947-3 |
---|---|
product certifications | CE |
protective treatment | TH |
IP degree of protection | IP20 conforming to IEC 60529 (with terminal cover) |
ambient air temperature for operation | -20…70 °C |
ambient air temperature for storage | -40…80 °C |
fire resistance |
850 °C fuse cover conforming to IEC 60695-2-1 960 °C body conforming to IEC 60695-2-1 |
height | 162 mm |
width | 186 mm |
depth | 116 mm |
net weight | 2 kg |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 2.181 kg |
Package 1 Height | 16.5 cm |
Package 1 width | 19.0 cm |
Package 1 Length | 23.5 cm |
Unit Type of Package 2 | S06 |
Number of Units in Package 2 | 14 |
Package 2 Weight | 43.534 kg |
Package 2 Height | 75.0 cm |
Package 2 width | 60.0 cm |
Package 2 Length | 80.0 cm |
Warranty | 18 months |
---|