Power Factor controller, PowerLogic PFC Controller, VPL 12...

Brand: Schneider Electric
Product Code: VPL12N
Availability: Check availability
VAT-exclusive price: 86.779,00
VAT-inclusive price: 104.134,80

Power Factor controller, PowerLogic PFC Controller, VPL 12

 
 

Main
range PowerLogic
product name PowerLogic PFC Controller
device short name VPL12
product or component type Power factor controller
Complementary
number of step output contacts 12
[Us] rated supply voltage 90...550 V AC
<= 999 kV AC with external VT
measurement current 0…5 A
measurement voltage 90…550 V AC 50/60 Hz
operating mode Manual or automatic
number of quadrant operation for generator application 4
device connection Communication protocol: Modbus interface: RS485
input function Switch: 1 x dry contact
colour code Front: dark grey RAL 7016
display type Backlit LCD
display size 56 x 25 mm
function available Manual programming
Automatic initialisation
Automatic detection
Advanced programming (expert)
Any step sequence
metering type Power factor and displacement PF (signed, four quadrant)
Total current harmonic distortion THD (I)
Power factor average over lifetime
Temperature maximum
Phase current I1, I2, I3 RMS on load
Active power P, P1, P2, P3 on load
Reactive power Q, Q1, Q2, Q3 on load
Apparent power S, S1, S2, S3 on load
Voltage U21, U32, U13, V1, V2, V3 on load
type of measurement Capacitor current overload Irms/I1
Individual voltage harmonic
Power factor
Operating time
Cos φ
Ambient temperature inside the cubicle
Tan φ
information displayed Number of switching cycles per step
Individual step size in kVAr
Remaining step capacity in %
type of alarms Step power loss (< 75 %) / Action: message and alarm contact + step blocked
Step faulty / Action: message and alarm contact + step blocked
High current (> 6 A CT) / Action: message and alarm contact
Hunting (unstable regulation) / Action: message and alarm contact + step blocked
Low current (< 15 mA CT) / Action: message and alarm contact
Overcompensation / Action: message and alarm contact
Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off
Overtemperature (50 °C) / Action: message and alarm contact + step switched off
Overtemperature (30 °C) / Action: fan switch
Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped
Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
data recording 5 alarms
Operational Hours alarm 100000 h without maintenance
Operational counter alarm 65000 cycles without maintenance
input type Phase to phase
Phase to neutral
Insensitive to CT polarity
Insensitive to phase rotation polarity
Current input CT...X/5 A and X/1 A
output type Control relay: 0.2 A 110 V DC
Control relay: 1 A 48 V DC
Control relay: 2 A 400 V AC 50/60 Hz
Control relay: 1 A 24 V DC
Control relay: 5 A 250 V AC 50/60 Hz
Control relay: 5 A 120 V AC 50/60 Hz
Fan: 5 A 250 V AC 50/60 Hz
Fan: 1 A 48 V DC
Alarm relay: 5 A 250 V AC 50/60 Hz
Alarm relay: 1 A 48 V DC
Maximum at the common terminal 10 A
settings operating mode Automatic
Manual
type of setting Choice of stepping programs: auto
Choice of stepping programs: LIFO
Choice of stepping programs: linear
Delay between 2 successive switch on the same step: 5...1200 s
Step configuration programming: auto
Step configuration programming: off
Step configuration programming: fixed
Target cos phi: 0.7 inductive...0.7 capacitive
Target cos phi: dual cos φ
measurement accuracy Voltage +/- 1 %
Current +/- 1 %
Frequency +/- 1 %
Energy (P,Q,S) +/- 2 %
Cos φ +/- 2 %
Total voltage harmonic distortion THD (U) +/- 2 %
Individual voltage harmonic +/- 3 %
Temperature +/- 3 °C
time delay range 1...6500 s (on reconnection)
1...6500 s (on response)
provided equipment User manual
mounting mode Flush-mounted
mounting support Panel - thickness: 1…3 mm
mounting location In cabinet
cut-out dimensions 138 x 138 mm
height 144 mm
width 144 mm
depth 58 mm
net weight 0.6 kg
Environment
standards IEC 61000-6-4
UL 61010-1
EN 61010-1
IEC 61000-6-2
IEC 61326-1
product certifications EAC
NRTL
cNRTL
CE
IP degree of protection Front face: IP41
Rear face: IP20
operating altitude <= 2000 m
ambient air temperature for operation -20…60 °C
ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 724.0 g
Package 1 Height 9.2 cm
Package 1 width 17.7 cm
Package 1 Length 18.4 cm
Unit Type of Package 2 P06
Number of Units in Package 2 64
Package 2 Weight 58.408 kg
Package 2 Height 75.0 cm
Package 2 width 60.0 cm
Package 2 Length 80.0 cm
Unit Type of Package 3 S03
Number of Units in Package 3 8
Package 3 Weight 6.301 kg
Package 3 Height 30.0 cm
Package 3 width 30.0 cm
Package 3 Length 40.0 cm

Main
range PowerLogic
product name PowerLogic PFC Controller
device short name VPL12
product or component type Power factor controller
Complementary
number of step output contacts 12
[Us] rated supply voltage 90...550 V AC
<= 999 kV AC with external VT
measurement current 0…5 A
measurement voltage 90…550 V AC 50/60 Hz
operating mode Manual or automatic
number of quadrant operation for generator application 4
device connection Communication protocol: Modbus interface: RS485
input function Switch: 1 x dry contact
colour code Front: dark grey RAL 7016
display type Backlit LCD
display size 56 x 25 mm
function available Manual programming
Automatic initialisation
Automatic detection
Advanced programming (expert)
Any step sequence
metering type Power factor and displacement PF (signed, four quadrant)
Total current harmonic distortion THD (I)
Power factor average over lifetime
Temperature maximum
Phase current I1, I2, I3 RMS on load
Active power P, P1, P2, P3 on load
Reactive power Q, Q1, Q2, Q3 on load
Apparent power S, S1, S2, S3 on load
Voltage U21, U32, U13, V1, V2, V3 on load
type of measurement Capacitor current overload Irms/I1
Individual voltage harmonic
Power factor
Operating time
Cos φ
Ambient temperature inside the cubicle
Tan φ
information displayed Number of switching cycles per step
Individual step size in kVAr
Remaining step capacity in %
type of alarms

Similar products:


Schneider Electric regulator - Varplus Logic - VPL 6;VPL06N

Power Factor controller, PowerLogic PFC Controller, VPL 6
-
Need to order

(Out of stock)

 
 
69.433,00

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products