Circuit breaker, ComPacT NSX630H, 70kA/415VAC, 3 poles, MicroLogic Vigi 7.3E trip unit 570A
range | ComPacT new generation |
---|---|
product name | ComPacT NSX new generation |
device short name | NSX630H |
product or component type | Earth leakage circuit breaker |
device application | Distribution |
poles description | 3P |
protected poles description | 3D |
[In] rated current | 570 A at 40 °C |
[Ue] rated operational voltage | 440 V AC 50/60 Hz |
network type | AC |
network frequency | 50/60 Hz |
suitability for isolation | Yes conforming to EN/IEC 60947-2 |
utilisation category | Category A |
[Icu] rated ultimate short-circuit breaking capacity |
100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
Performance level | H 70 kA 415 V AC |
trip unit name | Micrologic 7.3 E |
trip unit technology | Electronic |
trip unit protection functions | LSIR |
control type | Toggle |
Circuit breaker mounting mode | Fixed |
[Ui] rated insulation voltage | 500 V AC 50/60 Hz |
---|---|
[Uimp] rated impulse withstand voltage | 8 kV |
[Ics] rated service short-circuit breaking capacity |
100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
mechanical durability | 15000 cycles |
electrical durability |
8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In |
power dissipation per pole |
45.49 W N 45.49 W L1 and L3 38.99 W L2 |
mounting support | Backplate |
mounting position |
Horizontal and vertical Flat on the back |
upside connection | Front |
downside connection | Front |
connection pitch | 45 mm |
protection type |
L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection R : for earth-leakage protection |
trip unit rating | 570 A at 40 °C |
Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
[Ir] long-time protection pick-up adjustment range | 250...570 A |
Long-time protection delay adjustment type tr | Adjustable |
[tr] long-time protection delay adjustment range |
15…400 s at 1.5 x Ir 0.5…16 s at 6 x Ir 0.35…11 s at 7.2 x Ir |
thermal memory | 20 minutes before and after tripping |
Short-time protection pick-up adjustment type Isd | Adjustable |
[Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
Short-time protection delay adjustment type tsd | Adjustable |
[tsd] Short-time protection delay adjustment range |
0…0.4 s I²t=off 0.1…0.4 s I²t=on |
Instantaneous protection pick-up adjustment type Ii | Adjustable |
[Ii] instantaneous protection pick-up adjustment range | 1.5...12 x In |
earth-leakage protection | Integrated |
earth-leakage protection class | Class A |
Earth-leakage protection sensitity adjustment type IΔn | Adjustable |
[IΔn] earth-leakage protection sensitivity adjustment range |
300 mA 500 mA 1 A 3 A 5 A 10 A |
Earth-leakage protection specific mode | OFF using the IΔn rotary switch |
Earth-leakage protection time delay adjustement type Δt | Adjustable |
[Δt] Earth-leakage protection time delay adjustment range |
0 ms 60 ms 150 ms 500 ms 1 s |
zone selective interlocking ZSI | Without |
Number of slots for electrical auxiliaries | 6 slot(s) |
local signalling |
Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
display type | LCD display |
type of measurement | Energy meter |
communication of data |
Time-stamped histories and event tables Maintenance indicators Instantaneous and demand values Maximeters/minimeters Protection and alarm settings Power quality Energy metering Demand current and power |
Width (W) | 140 mm |
Height (H) | 255 mm |
Depth (D) | 110 mm |
net weight | 6.2 kg |
standards | EN/IEC 60947 |
---|---|
product certifications |
CCC EAC Marine |
overvoltage category | Class II |
electrical shock protection class | Class II |
pollution degree | 3 conforming to IEC 60664-1 |
IP degree of protection | IP40 conforming to IEC 60529 |
IK degree of protection | IK07 conforming to IEC 62262 |
ambient air temperature for operation | -25…70 °C |
ambient air temperature for storage | -40…85 °C |
relative humidity | 0…95 % |
operating altitude |
0...2000 m without derating 2000 m...5000 m with derating |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 7.5 kg |
Package 1 Height | 16.8 cm |
Package 1 width | 25.5 cm |
Package 1 Length | 14.0 cm |