Harmony, Interface plug-in relay, 8 A, 2 CO, 230 V AC
Main
range of product |
Harmony Electromechanical Relays |
series name |
Interface relay |
product or component type |
Plug-in relay |
device short name |
RSB |
contacts type and composition |
2 C/O |
contact operation |
Standard |
[Uc] control circuit voltage |
230 V AC 50/60 Hz |
[Ithe] conventional enclosed thermal current |
8 A at -40…40 °C |
status LED |
Without |
control type |
Without push-button |
Complementary
shape of pin |
Flat (PCB type) |
average coil resistance |
33000 Ohm network: AC at 20 °C +/- 10 % |
[Ue] rated operational voltage |
184...345 V AC 50/60 Hz |
[Ui] rated insulation voltage |
400 V conforming to EN/IEC 60947 |
[Uimp] rated impulse withstand voltage |
3.6 kV conforming to IEC 61000-4-5 |
contacts material |
Silver alloy (AgNi) |
[Ie] rated operational current |
4 A (AC-1/DC-1) NC conforming to IEC
8 A (AC-1/DC-1) NO conforming to IEC |
minimum switching current |
10 mA |
maximum switching voltage |
300 V DC conforming to IEC |
minimum switching voltage |
12 V |
maximum switching capacity |
2000 VA/224 W |
resistive rated load |
8 A at 250 V AC
8 A at 28 V DC |
minimum switching capacity |
120 mW at 10 mA, 12 V |
operating rate |
<= 600 cycles/hour under load
<= 18000 cycles/hour no-load |
mechanical durability |
5000000 cycles |
electrical durability |
100000 cycles, 8 A at 250 V, AC-1 NO
100000 cycles, 4 A at 250 V, AC-1 NC |
operating time |
20 ms operating
20 ms reset |
average coil consumption |
0.75 VA AC |
drop-out voltage threshold |
>= 0.15 Uc AC |
safety reliability data |
B10d = 100000 |
protection category |
RT I |
test levels |
Level A group mounting |
operating position |
Any position |
net weight |
0.014 kg |
sale per indivisible quantity |
10 |
device presentation |
Complete product |
Environment
dielectric strength |
1000 V AC between contacts
2500 V AC between poles
5000 V AC between coil and contact |
standards |
CSA C22.2 No 14
UL 508
EN/IEC 61810-1 |
product certifications |
CSA
EAC
UL |
ambient air temperature for storage |
-40…85 °C |
vibration resistance |
+/- 1 mm (f= 10…55 Hz) conforming to EN/IEC 60068-2-6 |
IP degree of protection |
IP40 conforming to EN/IEC 60529 |
shock resistance |
10 gn (duration = 11 ms) for not operating conforming to EN/IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to EN/IEC 60068-2-27 |
ambient air temperature for operation |
-40…70 °C (AC) |
Packing Units
Unit Type of Package 1 |
PCE |
Number of Units in Package 1 |
1 |
Package 1 Weight |
13 g |
Package 1 Height |
1.2 cm |
Package 1 width |
2 cm |
Package 1 Length |
2.9 cm |
Unit Type of Package 2 |
BB1 |
Number of Units in Package 2 |
10 |
Package 2 Weight |
160 g |
Package 2 Height |
1.7 cm |
Package 2 width |
2.5 cm |
Package 2 Length |
31.1 cm |
Unit Type of Package 3 |
S01 |
Number of Units in Package 3 |
350 |
Package 3 Weight |
5.778 kg |
Package 3 Height |
15 cm |
Package 3 width |
15 cm |
Package 3 Length |
40 cm |
Contractual warranty
Warranty |
18 months |