Helmholz ''TB20-C, PROFINET IO Bus Coupler
The PROFINET bus coupler is designed to connect a PROFINET bus to TB20 peripheral modules. It can accommodate up to 63 modules of any kind connected in series with...
VAT-exclusive price: 23.924,48 |
VAT-inclusive price: 28.709,37 |
The PROFINET bus coupler is designed to connect a PROFINET bus to TB20 peripheral modules. It can accommodate up to 63 modules of any kind connected in series with the bus coupler. The bus coupler supports hot-swapping for replacing modules during operation. In addition, it will recognize all connected peripheral modules and assign each module the corresponding inputs/outputs from the process image table. A functioning TB20 configuration will always require a bus coupler and at least one peripheral module.
- Modules can be replaced during operation (hot-swapping)
- 24 V DC power supply
- Integrated power supply unit for powering peripheral modules (2.5 A)
- Supplies the system’s I/O voltage (24 VDC)
- USB device port for online diagnostics, configuring parameters, setup, and firmware updates with "TB20 ToolBox"
- TB20 ToolBox simulation for commissioning the I/O system without a higher-level controller in order to test the system's operation (I/O check)
- Concealed "factory reset" switch for restoring the module to its factory settings
- I/O device as per PROFINET IO (IEC 61158-6-10)
- Integrated 2-port switch
- Full-duplex transmission rate of 100 Mbps
- 340 byte I/O data
- Up to 63 peripheral modules
- Conformance Class C
- Media Redundancy Protocol (MRP)
- Automatic addressing / hot-swapping (LLDP, DCP)
- Topology detection
- I&M data
- Diagnostic alarms, process alarms, pull/plug alarms
- Integration using GSDML file
- 7 LEDs, one of them bi-color
General information | |
Order number | 600-180-1AA11 |
Article name | TB20-C, PROFINET IO bus coupler |
Scope of delivery | Bus coupler PROFINET IO, 24 V power supply connector, bus cover element, base module |
Dimensions (DxWxH) | 110 x 35 x 73 mm |
Weight | Approx. 115 g |
PROFINET interface | |
Number | 2 |
Protocol | PROFINET IO as defined in IEC 61158-6-10 |
Physical layer | Ethernet |
Transmission rate | 100 Mbps full duplex |
I/O image size | 340 bytes |
Connection | RJ45 |
integrated switch | Yes |
Features | Conformance Class C, Media Redundancy Protocol (MRP), automatic addressing / topology detection (LLDP, DCP), PTCP, statistics counter |
Alarm functions | Diagnostic alarms, process alarms, pull/plug alarms |
Minimum cycle time | 250 µsec. |
IRT bridge delay | < 3 µsec. |
USB interface | |
Number | 1 |
Protocol | Full-speed USB 1.1 device |
Connection | Mini-USB |
Isolation voltage | 1.5 kV |
Electrical isolation | Yes |
Number of modules that can be connected in series | 63 |
Voltage supply | 24 V DC, 18...28 V DC |
Current draw | |
Current draw without modules (internal) | 75 mA |
Power supply for modules | 5 V DC, max 2.5 A |
Power dissipation | Max. 8 W |
Installation position | Any |
Ambient conditions | |
Ambient temperature | 0 °C … +60 °C |
Transport and storage temperature | -20 °C … +80 °C |
Relative air humidity | 95 % r H without condensation |
Protection rating | IP 20 |
Certifications | CE, UL |
UL | |
Surrounding Air Temperature | 0 °C … +50 °C |
Pollution degree | 2 |
CE | |
Noise immunity | DIN EN 61000-6-2 “EMC Immunity” |
Interference emission | DIN EN 61000-6-4 “EMC Emission” |
Vibration and shock resistance |
DIN EN 60068-2-8:2008 “Vibration”, DIN EN 60068-27:2010 “Shock“ |
RoHS | Yes |
REACH | Yes |
Similar products:
Helmholz ''TB20-C, CANopen® Slave Bus Coupler
The CANopen bus coupler is designed to connect a CAN bus to TB20 peripheral modules. It supports the CANopen protocol as defined in DS301 and uses the DSP-401 profile
-
(Out of stock)
18.751,62
Helmholz ''TB20-C, PROFIBUS DP Bus Coupler
The PROFIBUS-DP bus coupler is designed to connect a PROFIBUS bus to TB20 peripheral modules. It supports the DP-V0 and DP-V1 protocols. It will recognize all connected
-
(Out of stock)
20.044,83
Helmholz ''TB20-C, ModbusTCP Bus Coupler
The Modbus/TCP bus coupler makes it possible to access data from peripheral modules using the Modbus/TCP protocol, but can accommodate up to 64 modules of any kind
-
(Out of stock)
21.338,05